Item

Function

VF1

Turn the zebra indication on the

 

viewfinder connected to the VF1

 

connector on/off.

 

 

VF2

Turn the zebra indication on the

 

viewfinder connected to the VF2

 

connector on/off.

 

 

MONITOR

Turn the zebra indication on the monitors

 

connected to the MONITOR OUT

 

connectors on/off.

 

 

VBS

Turn the zebra indication on a device

 

connected via the REMOTE connector

 

on/off.

 

 

ZEBRA TYPE

Select the zebra(s) to be displayed:

 

1, 2, or 1&2

 

 

ZEBRA1 LEVEL

Adjust the level (50 to 109%) of the zebra

 

1 indication (factory setting: 70%).

 

 

WIDTH

Adjust the width (0 to 30%) of the zebra 1

 

indication (factory setting: 10%).

 

 

ZEBRA2

Adjust the level (50 to 109%) of the zebra

 

2 indication (factory setting: 100%).

 

 

3-6-7 Setting the Cursor Indication

You can display a cursor on the viewfinder and monitor screen.Example: Box cursor

Setting the cursor indication is performed on the <CURSOR> page of the USER (OPERATION) menu.

<CURSOR> page

 

<CURSOR>

 

U07

 

 

VF1

 

:BOFF

 

 

VF2

 

: OFF

 

 

MONITOR

: OFF

 

 

BOX/CROSS

:

BOX

 

 

H

POSITION

:

0

 

 

V

POSITION

:

0

 

 

WIDTH

:

960

 

 

HEIGHT

:

540

 

 

 

 

 

 

 

 

 

 

 

 

 

Menu item

Function

 

 

 

VF1

Turn the cursor indication on the viewfinder

 

 

connected to the VF1 connector on/off.

 

 

 

 

VF2

Turn the cursor indication on the viewfinder

 

 

connected to the VF2 connector on/off.

 

 

 

 

 

 

Menu item

Function

MONITOR

Turn the cursor indication on the monitors

 

connected to the MONITOR OUT

 

connectors on/off.

 

 

BOX/CROSS

Select the type of the cursor to be displayed.

 

 

H POSITION

Adjust the horizontal position of the center

 

(–960 to 960).

 

 

V POSITION

Adjust the vertical position of the center

 

(–540 to 540).

 

 

WIDTH

Adjust the width (from the center to right or

 

left side) of the cursor (16 to 1920).

 

 

HEIGHT

Adjust the height (from the center to top or

 

bottom) of the cursor (16 to 1080).

 

 

3-6-8 Checking the Power Voltage

The settings of the NEAR END and END values to warn of low voltage of a power supply can be checked on the <BATTERY ALARM> page of the USER (OPERATION) menu.

<BATTERY ALARM> page

 

<BATTERY

ALARM> U16

 

 

DC IN

(24V)

24.2V

 

 

TYPE:BAC

ADP

 

 

 

NEAR

END

:

(22.2)

 

 

END

 

 

:

(21.6)

 

 

DC IN

(12V)

12.8V

 

 

TYPE:

AC

ADP

 

 

 

NEAR

END

:

(11.1)

 

 

END

 

 

:

(10.8)

 

 

 

 

 

 

 

 

 

 

 

 

 

Menu item

Indication

 

 

DC IN (24V)

Voltage of the 24-V power

 

 

 

 

TYPE

Select the type of the 24-V power source.

 

 

 

 

NEAR END

NEAR END value specified for the 24-V

 

 

power source of the selected type

 

 

 

 

END

END value specified for the 24-V power

 

 

source of the selected type

 

 

 

 

DC IN (12V)

Voltage of the 12-V power

 

 

 

 

TYPE

Select the type of the 12-V power source.

 

 

 

 

NEAR END

NEAR END value specified for the 12-V

 

 

power source of the selected type

 

 

 

 

END

END value specified for the 12-V power

 

 

source of the selected type

 

 

 

 

 

 

 

This page is intended for display only. You can only switch the type. If you want to change the values, use the <BATT ALARM SET> page of the MAINTENANCE menu.