OPERATION menu

Page title &

No.

Item

Default

 

Settings

Remarks

purpose

 

 

 

 

 

 

<ASSISTANT PNL>

13

FORMAT 1

23P 444

 

NO ASSIGN,

Register the formats to be

Registering the

(U13)

 

 

 

23P 444, S23P 444,

selected on the subdisplay.

 

 

 

 

24P 444, S24P 444,

Select from among the

formats to be

 

 

 

 

 

 

 

 

25P 444, S25P 444,

formats displayed on the

selected on the

 

 

 

 

 

 

 

 

29P 444, S29P 444,

corresponding <FORMAT

assistant panel

 

 

 

 

 

 

 

 

S30P 444, 50I 444,

SEL> subpage.

 

 

 

 

 

 

 

 

 

 

59I 444, 23P 422,

 

 

 

 

 

 

S23P 422, 24P 422,

 

 

 

 

 

 

S24P 422, 25P 422,

 

 

 

 

 

 

S25P 422, 29P 422,

 

 

 

 

 

 

S29P 422, S30P 422,

 

 

 

 

 

 

50P 422, S50P 422,

 

 

 

 

 

 

59P 422, S59P 422,

 

 

 

 

 

 

S60P 422, 50I 422,

 

 

 

 

 

 

59I 422

 

 

 

FORMAT 2

S23P 444

Same as above

 

 

 

FORMAT 3

S59P 444

Same as above

 

<SWITCH

14

AS1

ND

 

OFF, ND, CC, REC

Select from among the

ASSIGN>

(U14)

AS2

CC

 

REVIEW, PB(VF),

functions displayed on the

Setting the

 

 

 

 

VF709GAM,

corresponding subpage.

 

AS3

OFF

 

MONI709GAM, FAN

 

functions of the

 

 

 

 

 

 

 

MODE

 

assignable buttons

 

 

 

 

 

and switch

 

AS4

OFF

 

OFF, AWB, BARS,

 

 

 

 

 

 

TEST1

 

 

 

RE - ROTATION

STD

 

STD, RVS

Specify operation mode of the

 

 

 

 

 

 

MENU SEL/ENTER dial.

 

 

 

 

 

 

STD: Clockwise rotation

 

 

 

 

 

 

advances the pointer/

 

 

 

 

 

 

cursor or increases values

 

 

 

 

 

 

on the menu screen.

 

 

 

 

 

 

RVS: Counterclockwise

 

 

 

 

 

 

rotation advances the

 

 

 

 

 

 

pointer/cursor or increases

 

 

 

 

 

 

values on the menu

 

 

 

 

 

 

screen.

<GAIN ASSIGN>

15

GAIN

[L]

0 dB

3, 0, 3, 6, 9, 12 dB

Assign the values for the gain

Specifying the gain

(U15)

 

[M]

6 dB

3, 0, 3, 6, 9, 12 dB

switch of the RM-B150.

 

 

 

switch settings

 

 

 

 

 

 

 

 

[H]

12 dB

3, 0, 3, 6, 9, 12 dB

 

 

 

 

 

<BATTERY

16

DC IN (24V)

 

 

 

 

ALARM>

(U16)

TYPE

AC ADP

 

BATT1, BATT2, AC ADP

 

Confirming the

 

 

 

 

NEAR END

(22.2)

 

 

display only (Setting is

operating power

 

 

 

 

 

 

 

 

achieved using the

voltage

 

 

 

 

 

 

 

 

 

 

MAINTENANCE menu.)

 

 

 

 

 

 

 

 

END

(21.6)

 

 

display only (Setting is

 

 

 

 

 

 

achieved using the

 

 

 

 

 

 

MAINTENANCE menu.)

 

 

DC IN (12 V)

 

 

 

 

 

 

TYPE

AC ADP

 

BATT1, BATT2, AC ADP

 

 

 

NEAR END

(11.1)

 

 

display only (Setting is

 

 

 

 

 

 

achieved using the

 

 

 

 

 

 

MAINTENANCE menu.)

 

 

END

(10.8)

 

 

display only (Setting is

 

 

 

 

 

 

achieved using the

 

 

 

 

 

 

MAINTENANCE menu.)

 

 

 

 

 

 

 

Settings Detailed and Configuration Menu 4 Chapter