manually adjusted values of the camera will be reset to the reference values that have been stored in the reference file. At shipment, the reference file with the initial settings is stored in built-in memory.

The initial settings can be modified, as required, then stored as the new reference file.

For file operation, use the <REFERENCE> page of the FILE menu. You can also use the MSU-900/950 Master Setup Unit for file operation.

You can back up the reference file in a “Memory Stick.”

Notes

In Cine mode, the reference file data are fixed as those at shipment and cannot be modified.

As relative adjustment values with regard to the reference file data are stored in a scene file, if data of the reference file are modified, the scene files also need modification.

Items stored

The items that are stored in the reference file are marked with “a” in the “R” column of the table in “5-2 List of Items Stored in Files”.

User-Gamma file

The gamma-curve data (User Gamma) created using CvpFileEditor application software can be loaded to the camera via a “Memory Stick.” This enables reproduction of images closer to those that individual users wish to reproduce.

For file operation, use the <USER GAMMA> page of the FILE menu.

The User-Gamma file is stored in built-in memory. Backup of the User-Gamma file in a “Memory Stick” is not possible.

Note

In Cine mode, operation of the User-Gamma file via a “Memory Stick” is not possible.

OHB fileThe OHB file stores the offset values of items specific to the CCD unit.

For file operation, use the <OHB FILE> page of the FILE menu. You can also use the MSU-900/950 Master Setup Unit for this operation.

Note

In Cine mode, the OHB file can be retrieved automatically, but the data in the OHB file cannot be modified.

Items stored

The items that are stored in the OHB file are marked with “a” in the “O” column of the table in “5-2 List of Items Stored in Files”.

5-2 List of Items Stored in Files

The items that are stored in scene files, the reference file, the lens files, and the OHB file are listed in the table below.

For details on setting values, see the corresponding items in the table in “4-3 Menu List” (page 55).

S: Scene file

R: Reference file

L: Lens file

O: OHB file

Menu page

Item

S

R

L

O

(No.)

 

 

 

 

 

<VIDEO LEVEL>

WHITE [R] [G] [B]

a

a

 

 

(P02)

 

 

 

 

 

WHITE [R] [B]

a

a

a

 

 

 

 

 

 

 

 

 

 

BLACK [R] [G] [B] [M]

a

a

 

 

 

 

 

 

 

 

 

FLARE [R] [G] [B]

a

a

a

 

 

 

 

 

 

 

 

V MOD [R] [G] [B] [M]

 

 

 

 

 

 

 

 

 

 

 

FLARE ON/OFF

a

a

 

 

 

 

 

 

 

 

 

V MOD ON/OFF

 

a

 

 

 

 

 

 

 

 

<GAMMA>

LEVEL [R] [G] [B] [M]

a

a

 

 

(P03)

 

 

 

 

 

COARSE

a

a

 

 

 

 

 

 

 

 

 

 

 

 

TABLE

a

a

 

 

 

 

 

 

 

 

 

GAMMA ON/OFF

a

a

 

 

 

 

 

 

 

 

<BLACK

LEVEL [R] [G] [B] [M]

a

a

 

 

GAMMA>

 

 

 

 

 

RANGE

a

a

 

 

(P04)

 

 

 

 

 

 

 

 

RANGE ON/OFF

a

a

 

 

 

 

 

 

 

 

 

BLACK GAMMA

a

a

 

 

 

ON/OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

<SATURATION>

SATURATION

a

a

 

 

(P05)

 

 

 

 

 

SATURATION ON/

a

a

 

 

 

 

 

 

OFF

 

 

 

 

 

LOW KEY SAT

a

a

 

 

 

 

 

 

 

 

 

RANGE

a

a

 

 

 

 

 

 

 

 

<KNEE>

K POINT

a

a

 

 

(P06)

[R] [G] [B] [M]

 

 

 

 

 

 

 

 

 

 

 

 

 

K SLOPE

a

a

 

 

 

[R] [G] [B] [M]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KNEE ON/OFF

a

a

 

 

 

 

 

 

 

 

 

KNEE SAT

a

a

 

 

 

 

 

 

 

 

 

KNEE SAT ON/OFF

a

a

 

 

 

 

 

 

 

 

 

AUTO KNEE

a

a

 

 

 

 

 

 

 

 

 

POINT LIMIT

a

a

 

 

 

 

 

 

 

 

 

SLOPE

a

a

 

 

 

 

 

 

 

 

<WHITE CLIP>

W CLIP [R] [G] [B] [M]

a

a

 

 

(P07)

 

 

 

 

 

W CLIP ON/OFF

a

a

 

 

 

 

 

 

 

 

 

 

 

Data Setting User of Retrieval and Storage 5 Chapter

List of Items Stored in Files

79