Warning/Error Messages

If battery power is low or a problem occurs at power on or during operation, a warning is given by an indicator flashing or various alarm indications.

Viewfinder screen

 

Subdisplay

RUN

Meaning

 

 

 

indicator

 

Basic status

Message

 

 

 

 

 

display (page 39)

 

 

 

 

BATT 12 V flashing

 

BATT 12 V flashing

Flashing

Voltage of the 12 V power becomes low,

 

 

 

 

reaching the specified NEAR END value.

 

 

 

 

 

BATT 12 V quick

 

BATT 12 V quick

Quick

Voltage of the 12 V power becomes too

flashing

 

flashing

flashing

low, reaching the specified END value.

 

 

 

 

 

BATT 24 V flashing

 

BATT 24 V flashing

Flashing

Voltage of the 24 V power becomes low,

 

 

 

 

reaching the specified NEAR END value.

 

 

 

 

 

BATT 24 V quick

 

BATT 24 V quick

Quick

Voltage of the 24 V power becomes too

flashing

 

flashing

flashing

low, reaching the specified END value.

 

 

 

 

 

 

TEMPERATURE CARE

 

 

Temperature inside the camera raises.

 

 

 

 

 

 

TEMPERATURE

 

 

Temperature inside the camera raises to

 

WARNING

 

 

the limit.

 

 

 

 

 

 

SHUTDOWN CAMERA

 

 

The camera must be turned off for safety.

 

 

 

 

 

 

OHB/SIDE FAN NG!

 

 

The fan near the CCD or the fan near the

 

 

 

 

side panel stops.

 

 

 

 

 

 

PS FAN NG!

 

 

The fan near the power unit stops.

 

 

 

 

 

CAM?

OHB NG!

 

 

Abnormality of the CCD unit

 

 

 

 

 

CAM?

AD BOARD NG!

 

 

Abnormality of the AD board

 

 

 

 

 

CAM?

DPR BOARD NG!

 

 

Abnormality of the DPR board

 

 

 

 

 

CAM?

VDA BOARD NG!

 

 

Abnormality of the VDA board

 

 

 

 

 

CAM?

TR BOARD NG!

 

 

Abnormality of the TR board

 

 

 

 

 

CAM?

AT BOARD NG!

 

 

Abnormality of the AT board

 

 

 

 

 

 

I/F BOX NG!

 

Quick

An unknown interface box is connected.

 

 

 

flashing

 

 

 

 

 

 

 

UNKNOWN RECORDER

 

Quick

An unknown recorder is connected.

 

 

 

flashing

 

 

 

 

 

 

 

VTR ALARM

 

 

Alarm occurs at the SRW-1.

 

 

 

 

 

 

VTR WARNING

 

 

Warning occurs at the SRW-1.

 

 

 

 

 

Appendixes

Using the MSU-900/950 91