Settings and Adjustments Basic 3 Chapter
3-2-7 Confirmation of the Time Code and Tape Remaining
When the
Time code/tape remaining display page
TCR 00:00:00:00 20min
The time code is displayed on the first line, and the approximate tape remaining is displayed on the second line, in the range of 1 to 99 min.
Time code that is displayed on the first line
Indication | Meaning |
TCR 00:00:00:00 | Time code data of the LTC reader |
|
|
TCR 00:00.00:00 | Time code data of the LTC reader (DF) |
|
|
TCR.00:00:00:00 | Time code data of the VITC reader |
|
|
UBR 00 00 00 00 | User bit data of the LTC reader |
|
|
UBR.00 00 00 00 | User bit data of the VITC reader |
|
|
TCG 00:00:00:00 | Time code data of the time code |
| generator |
|
|
TCG 00:00:00.00 | Time code data of the time code |
| generator (DF) |
|
|
UBG 00 00 00 00 | User bit data of the time code |
| generator |
|
|
CTL | Data of the CTL counter |
|
|
T*R 00:00:00:00 | Time code cannot be read with the |
| LTC reader |
|
|
U*R 00 00 00 00 | User bit cannot be read with the LTC |
| reader |
|
|
T*R.00:00:00:00 | Time code cannot be read with the |
| VITC reader |
|
|
U*R.00 00 00 00 | User bit cannot be read with the VITC |
| reader |
|
|
The type of the displayed time code data is linked with the
3-2-8 Confirmation of the Power
Voltage and Selection of Fan
Operation Mode
The values in voltage of the power sources connected to the camera can be confirmed on the subdisplay.
On the same page, the operation mode of the built-in fans can also be selected.
Voltage confirmation/Fan Operation mode select page
12
11.4V 24.1V FAN:AUTO1
At 1 and 2 on the first line, the values in voltage of the
If the voltage falls to the NEAR END level, the indication starts flashing. If the voltage falls further down to the END level, the indication flashes rapidly.
The NEAR END and END levels can be set on the <BATT ALARM SET> page of the MAINTENANCE menu.
On the second line, Fan Operation mode can be changed.
Setting | Operation of the fans |
AUTO1 (default) | The fans rotate at the standard speed. |
|
|
AUTO2 | The fans rotate at the minimum speed |
| equivalent to the MIN speed in REC |
| mode. In other conditions, the fans |
| rotate at the speed equivalent to the |
| AUTO1 speed. |
|
|
MIN | The fans rotate at the minimum speed. |
|
|
MAX | The fans rotate at the maximum speed. |
|
|
3-2-9 ON/OFF of the Character Indication
Superimposition of character data onto camera images can be activated or deactivated by output destination.
Character indication setting page
VF1:ON
MON:ON VBS:ON
VF1
Viewfinder connected via the VF1 connector (default: ON)
MON
Monitors connected via the MONITOR OUT HD SDI connectors (default: ON)
VBS
Monitors connected via the TEST OUT and REMOTE connectors (default: ON)
32 | Basic Settings with the Subdisplay |
|
|