Settings and Adjustments Basic 3 Chapter

3-2-7 Confirmation of the Time Code and Tape Remaining

When the SRW-1 HD Portable Digital Recorder is attached to this camera, the time code of the recorder and approximate tape remaining (unit: minutes) can be confirmed on the subdisplay.

Time code/tape remaining display page

TCR 00:00:00:00 20min

The time code is displayed on the first line, and the approximate tape remaining is displayed on the second line, in the range of 1 to 99 min.

Time code that is displayed on the first line

Indication

Meaning

TCR 00:00:00:00

Time code data of the LTC reader

 

 

TCR 00:00.00:00

Time code data of the LTC reader (DF)

 

 

TCR.00:00:00:00

Time code data of the VITC reader

 

 

UBR 00 00 00 00

User bit data of the LTC reader

 

 

UBR.00 00 00 00

User bit data of the VITC reader

 

 

TCG 00:00:00:00

Time code data of the time code

 

generator

 

 

TCG 00:00:00.00

Time code data of the time code

 

generator (DF)

 

 

UBG 00 00 00 00

User bit data of the time code

 

generator

 

 

CTL -0:00:00:00

Data of the CTL counter

 

 

T*R 00:00:00:00

Time code cannot be read with the

 

LTC reader

 

 

U*R 00 00 00 00

User bit cannot be read with the LTC

 

reader

 

 

T*R.00:00:00:00

Time code cannot be read with the

 

VITC reader

 

 

U*R.00 00 00 00

User bit cannot be read with the VITC

 

reader

 

 

The type of the displayed time code data is linked with the SRW-1. Select the type of the displayed time code data on the SRW-1.

3-2-8 Confirmation of the Power

Voltage and Selection of Fan

Operation Mode

The values in voltage of the power sources connected to the camera can be confirmed on the subdisplay.

On the same page, the operation mode of the built-in fans can also be selected.

Voltage confirmation/Fan Operation mode select page

12

11.4V 24.1V FAN:AUTO1

At 1 and 2 on the first line, the values in voltage of the 12-V and 24-V power systems are displayed, respectively. If power is not supplied, “- -” is displayed.

If the voltage falls to the NEAR END level, the indication starts flashing. If the voltage falls further down to the END level, the indication flashes rapidly.

The NEAR END and END levels can be set on the <BATT ALARM SET> page of the MAINTENANCE menu.

On the second line, Fan Operation mode can be changed.

Setting

Operation of the fans

AUTO1 (default)

The fans rotate at the standard speed.

 

 

AUTO2

The fans rotate at the minimum speed

 

equivalent to the MIN speed in REC

 

mode. In other conditions, the fans

 

rotate at the speed equivalent to the

 

AUTO1 speed.

 

 

MIN

The fans rotate at the minimum speed.

 

 

MAX

The fans rotate at the maximum speed.

 

 

3-2-9 ON/OFF of the Character Indication

Superimposition of character data onto camera images can be activated or deactivated by output destination.

Character indication setting page

VF1:ON

MON:ON VBS:ON

VF1

Viewfinder connected via the VF1 connector (default: ON)

MON

Monitors connected via the MONITOR OUT HD SDI connectors (default: ON)

VBS

Monitors connected via the TEST OUT and REMOTE connectors (default: ON)

32