12 MAINTENANCE & TROUBLESHOOTING

12.5 Replacement of Fuses

To protect the FS-1570 from overcurrent and equipment fault, two fuses are provided in the PR-300 Power Supply Unit. If a fuse blows, find the cause before replacing it. If it blows again after replacement, request service.

CAUTION

Use the proper fuse.

Use of the wrong fuse can cause serious damage to the equipment and void the warranty.

Unit

Fuse

Power Supply Unit PR-300

10 A (100 VAC) or 5A (200 VAC)

 

and 20 A (24 VDC)

PR-300

FUSE

100V

10A

125V 20A

 

220V

5A

 

 

 

 

ON

ON

 

 

OFF

OFF

 

 

AC IN

DC IN

DC OUT

 

L N G

+ -

+ - 24V + -

PR-300

Note: The Power Supply Unit PR-850A, used with the FS-2570, does not have a fuse but a circuit breaker. If the breaker has tripped, find the reason before resetting the breaker (upward position).

BREAKER

POWER

ON

ON

OFF

AC INPUT 50/60Hz

DC OUTPUT

PR-850A