5.The display changes a shown below each time the [DISPLAY] key is pressed.

• Address & Adjusted Value Display

Remote commander LCD display

011C 6 8 S 0 1

 

 

 

 

 

 

adjusted value

address

 

 

 

 

item number

• Jitter Value & Adjusted Value Display

Remote commander LCD display

011O F F J 0 1

 

 

 

 

 

 

 

 

 

 

 

adjusted value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

jitter value

 

 

 

 

 

 

 

 

 

 

item

number

 

 

 

 

 

• Block Error Value & Adjusted Value Display

Remote commander LCD display

0110 6 3 B 0 1

 

 

 

 

 

 

 

 

 

 

 

adjusted value

 

 

 

 

 

 

 

 

 

 

 

 

 

block error value

 

 

 

 

 

 

 

 

 

 

item

number

 

 

 

 

 

Self-Diagnosis Display Mode

This set uses the self-diagnosis system in which if an error oc- curs in playback mode, the error is detected by the model con- trol and power control blocks of the microprocessor and infor- mation on the cause is stored as history in EEPROM.

By viewing this history in test mode, it helps you to analyze a fault and determine its location.

1.Setting the test mode (see page 12).

2.In the display check mode, press the [DISPLAY] key activates the self-diagnosis display mode where the LCD display as shown below.

Remote commander LCD display

0001 s t 0 * *

 

 

 

 

 

 

 

history code

 

error display code

 

3.Then, each time the N > key is pressed, LCD display de- scends by one as shown below. Also, the LCD display ascends by one when the . key is pressed.

1

• ADIP Error Value & Adjusted Value Display

Remote commander LCD display

 

011 0 5 9 A 0 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

adjusted value

 

 

 

 

 

 

 

 

 

 

 

 

 

ADIP error value

 

 

 

 

 

 

 

 

 

 

 

 

item

number

 

 

 

 

 

 

 

 

 

 

• Item Title Display

 

 

 

 

 

Remote commander LCD display

 

011 L r e f P w

0 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

adjusted value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

item title

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

item

number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

However in the power mode (item number 700’s), only the item is displayed.

0001 s t 0 * *

0001 s t 1 0 0

0001 s t 2 0 0

000 N

0 * *

000 N

 

 

1 0 0

000 N

 

 

2 0 0

000N - 1 0 * *

000N - 1 1 0 0

000N - 1 2 0 0

000N - 2 0 * *

000N - 2 1 0 0

000N - 2 2 0 0

000 R 0 0 0 0

1

6.Quit the manual mode, and press the x key to return to the test mode (display check mode).

Overall Adjustment Mode

Mode to adjust the servo automatically in all items.

Normally, automatic adjustment is executed in this mode at the repair.

For further information, refer to “Section 5 Electrical Adjustments” (see page 17).

4.Quit the self-diagnosis display mode, and press the x key to return to the test mode (display check mode).

– 14 –

Page 14
Image 14
Sony MZ-E800 service manual 011 C 6 8 S 0, F F J 0, 011 0 6 3 B 0, 000 1 s t