•Disc access by DELETE LAST CLIP, DELETE ALL CLIPS, QUICK FORMAT in the DISC menu, and so on: Stopped
•MENU button: OFF
•Unsaved current clip list: Save or clear
2 Connect the S400 connector on this unit to the
i.LINK (IEEE1394) connector on the remote computer, using an i.LINK cable.
File data
Transfer of files
Disc recorder (this unit) | Laptop computer, etc. | |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
i.LINK cable (not supplied)
Windows recognizes this unit as a removable disc, and displays one of the following icons on the remote computer’s task bar:
•Windows 2000:
•Windows XP:
The remote computer is now able to perform file operations when a disc is inserted into this unit.
Operation limitations during FAM connections
•With the exception of the EJECT button, recording buttons and playback control buttons are disabled.
•This unit cannot be controlled from any device connected to an external device connector.
•There is no signal output from this unit, and the message “PC REMOTE!” appears in the display of this unit and on the external monitor.
Operating on Files
Proceed as follows.
1 Start Explorer.
Check that a drive letter has been assigned to this unit. (The drive letter will differ depending on the number of other peripherals connected to the remote computer.)
2 Use Explorer to perform file operations on the disc loaded in this unit.
You can operate in the same way that you operate on local drives and files on network computers.
Notes
•If you power this unit off during an FAM connection, the data transferred thus far is discarded.
•All file operations are not possible for some types of files.
To eject discs from a remote computer
Right click the icon representing this unit in Explorer, and select “Eject” from the menu which appears.
To exit file operationsProceed as follows.
Note
Do not disconnect the cable before performing steps 1 to 3.
1 Do one of the following on the or icon displayed in the remote computer’s taskbar.
•Double click.
•Right click, and select one of the following commands from the menu which appears. Windows 2000: Unplug or eject hardware Windows XP: Safely Remove Hardware
The “Unplug or Eject Hardware” dialog box (Windows 2000) or the “Safety Remove Hardware” dialog box (Windows XP) appears.
2 Select “Sony XDCAM
The “Stop a Hardware device” dialog appears.
3 Select “Sony XDCAM
In Windows 2000, a confirmation message appears. In Windows XP, “Sony XDCAM
This unit can now resume normal operations. (The limitations described in “Operation limitations during FAM connections” (see page 63) no longer apply.)
4 Disconnect the i.LINK cable as required.
To make a reconnectionTo reconnect after exiting file operations, do one of the following, depending on whether an i.LINK cable is connected.
i.LINK cable is not connected: Connect this unit and a remote computer with an i.LINK cable.
Operations File 5 Chapter
File Operations in File Access Mode | 63 |
|
|