Preparations 2 Chapter

14Press the M/MARK1 or m/MARK2 button to select one of the following.

23.98PsF: Output as 23.98P.

2-3 PULL DOWN: Output after pulldown conversion to 59.94i.

15Press the SET button.

A confirmation message appears.

16Press the SET button to confirm the changes, or the RESET button to cancel them.

If you have pressed the SET button, power the unit off and on again to enable the changes.

Input and Output Signals in 24P (23.98P) Mode

The following tables show the signals input and output by the unit when “23.98PsF” and “2-3 PULL DOWN” are selected.

Input and output signals

I/O

Type

23.98PsF

2-3 PULL

 

 

 

DOWN

Input

Reference

23.98PsF

59.94i

signals

video input

reference signal

reference signal

 

 

 

 

 

HDSDI input

23.98PsF video and audio

 

 

signals

 

 

 

 

Input

LTC input

24-frame timecode

timecode

 

 

 

HDSDI LTC

 

 

 

 

 

 

input

 

 

 

 

 

 

Output

HDSDI

23.98PsF video

Video and

signals

output

and audio

audio signals

 

 

signals

pulled down to

 

 

 

59.94i

 

SDSDI output

No output

 

 

 

 

 

 

 

Composite

 

 

 

output

 

 

 

 

 

 

 

i.LINK DV

 

 

 

output

 

 

 

 

 

 

 

i.LINK TS

 

 

 

output

 

 

 

 

 

 

Timecode

LTC output

24-frame

30-frame

output

 

timecode

timecode after

HDSDI LTC/

 

 

pulldown

 

VITC output

 

 

 

conversion

 

 

 

 

SDSDI

 

 

RP188 LTC

 

 

 

output

 

 

 

 

 

 

 

SDSDI VITC

 

 

output

 

 

 

 

 

 

 

COMPOSITE

 

 

VITC output

 

 

 

 

 

 

Timecode display

Type

23.98PsF

2-3 PULL DOWN

LTC display

24-frame timecode

 

 

 

 

PDT display

30-frame timecode

 

 

after pulldown

VITC display

24-frame timecode

conversion

 

 

 

COUNTER display

24-frame signals

30-frame signals

 

 

after pulldown

 

 

conversion

 

 

 

Timecode in remote timecode mode

Type

23.98PsF

2-3 PULL DOWN

9-pin preset

24-frame timecode

 

timecode

 

 

 

 

 

9-pin preset

24-frame signals

30-frame signals

timer 1 (Counter)

 

after pulldown

 

 

conversion

 

 

 

9-pin scene

24-frame timecode

30-frame timecode

timecode

 

after pulldown

 

 

conversion

 

 

 

9-pin scene

24-frame signals

30-frame signals

timer 1 (Counter)

 

after pulldown

 

 

conversion

 

 

 

For more information about remote timecode mode, refer to the REMOTE (9-pin) Protocol Manual for the PDW series (not supplied).

Recording in 24P (23.98P) ModeRecording frame sequence and clip length

See the following figure for the frame sequence.

In 24P (23.98P) mode, recording start and stop timing is adjusted so that a recorded sequence always begins with an “A-frame” and ends with a “D-frame”. As a result, the number of frames in a clip is always a multiple of 4.

Recording timecode

When you preset timecode manually, select a multiple of 4 as the number of frames in the timecode, and adjust so that the preset timing begins with an “A-frame”.

The unit will then adjust so that the timecode at the start of recorded clips will have a number of frames that is a multiple of 4.

Notes

The above adjustments are not carried out when you preset timecode remotely.

No adjustments are made when you record external timecode. Therefore the number of frames in the

38 24P (23.98P) Mode Settings