17. Control by Telnet
Command | Contents | |
|
| |
RNG? | Input range setting value readout | |
Command format | RNG? <1><2>/[ ] | |
| <1> | : 0=Recording unit setting value, 1=Recording media data |
| <2> | : Measuring unit ID number |
|
| 0=Measuring unit 1 |
|
| 1=Measuring unit 1 |
|
| 2=Measuring unit 2 |
|
| 3=Measuring unit 2 |
|
| 4=Measuring unit 3 |
|
| 5=Measuring unit 3 |
|
| 6=Measuring unit 4 |
|
| 7=Measuring unit 4 |
Returned format | RNG : <1><2>...<16> | |
| <1> | : CH 1 input range code |
| <2> | : CH 2 input range code |
| . |
|
| . |
|
| . |
|
| <16> : CH 16 input range code | |
| Input range code | |
|
| 0=RSV, 1=10 V, 2=5 V, 3=2 V, 4=1 V, 5=0.5 V, 6=0.2 V, 7=0.1 V |
| Related command : RNG | |
|
| |
RPT? | Auto repeat status readout | |
Command format | RPT? /[ ] | |
Returned format | RPT : <1> | |
| <1> : 0=Other than below | |
|
| 1=Auto repeat — recording |
|
| 2=Auto repeat — rewinding |
| Related command : RPT | |
|
| |
SCH? | Search status | |
Command format | SCH? /[ ] | |
Returned format | SCH : <1> | |
| <1> : 0=Other than below (after | |
|
| 1=Search underway |
|
| 2=Search finished (FOUND) |
|
| 3=Search finished (NOT FOUND) |
| Related command : SCH | |
|
| |
SLF? | Diagnostics status | |
Command format | SLF? /[ ] | |
Returned format | SLF : <1> | |
| <1> : 0=Other than below (after | |
|
| 1=Diagnostics underway |
|
| 2=Diagnostics finished (OK) |
|
| 3=Diagnostics finished (NG) |
| Related command : SLF | |
| Related command : ERR? | |
|
| |
SPD? | Recording media speed readout | |
Command format | SPD? <1>/[ ] | |
| <1> : 0=Recording unit setting value, 1=Recording media data | |
Returned format | SPD : <1> | |
| <1> : 0=1 x, 1=1/2 x, 2=1/4 x, 3=1/8 x, 4=1/16 x, A=x2, B=x4, F=EXT | |
| Related command : SPD | |
|
|
|