18. Errors and Error Messages
When the recording unit malfunctions during diagnostics, calibration, recording or playback operation, the error code is displayed on the LCD screen. Take the appropriate measure based on the table below.
When using the recorder in a dusty surrounding, the data could not be played back (or verified during recording) and also an error code is displayed. In such a case, perform a play back inside a room. If the error code does not disappear after the appropriate measure has been taken or if the displayed error code is not listed in this manual, contact service engineer.
EH03 | 0C01 | Drive 1 write retries have exceeded the designated limit | |
|
| 0C02 | Drive 2 write retries have exceeded the designated limit |
|
| 1101 | Drive 1 read retries have exceeded the designated limit |
|
| 1102 | Drive 2 read retries have exceeded the designated limit |
|
| 3001 | Drive 1 format is not correct |
|
| 3002 | Drive 2 format is not correct |
|
|
|
|
| EH04 | 0001 | Hard disk not installed in drive 1 |
|
| 0002 | Hard disk not installed in drive 2 |
|
| 4401 | Drive 1 is faulty |
|
| 4402 | Drive 2 is faulty |
|
|
|
|
| EH90 | 0001 | Formatting of drive 1 failed |
|
| 0002 | Formatting of drive 2 failed |
|
|
|
|
| EH91 |
| No TOC found |
|
|
|
|
| EH92 |
| An invalid TOC was detected. |
|
|
|
|
| EH93 |
| Communication error occurred on HDD board |
|
|
|
|
| EH95 |
| Error occurred in peripherals |
|
|
| File system error |
|
|
| IDE controller error |
|
|
| StarFabric control error |
|
|
| PCI control error |
|
|
|
|
| EH96 |
| An unknown error occurred |
|
|
|
|
EA20 | 00xx | A/D calibration error occurred. xx is the channel. | |
|
|
|
|
| EA30 | 00xx | D/A calibration error occurred. xx is the channel. |
|
|
|
|
| EA60 |
| ADA flash memory error |
|
| 0001 | CAL data was not found |
|
| 0002 | Unable to access |
|
|
|
|
| EA70 |
| Measuring unit ID error |
|
|
|
|
| EA80 |
| ADA board error |
|
|
|
|
| EA90 |
| DMA timed out in REC |
|
|
|
|
| EA91 |
| DMA timed out in PB |
|
|
|
|
EP03 |
| Power failure | |
Battery- |
|
|
|
EP10 |
| Battery voltage is low | |
|
| ||
|
|
|
|
Ed50 |
| Communication error occurred between the IF board and ADA | |
|
|
| board |
|
|
|
|
| Ed60 |
| Communication error occurred between the DSP board and ADA |
|
|
| board |
|
|
|
|
| Ed70 |
| Communication error occurred between the IF board and DSP |
|
|
|
|
| Ed80 |
| Telnet communication error |
|
|
|
|
| ES30 |
| Error occurred between DPR board and DR board |
|
|
|
|
| ES40 |
| Error occurred between DPR board and IF board |
|
|
|
|
| ES50 |
| Error occurred between DR board and IF board |
|
|
|
|
EX30 |
| Sync Setting error/cable error | |
|
|
|
|
| EX31 |
| Sync No target/sync playback data |
|
|
|
|
| EX32 |
| Sync Recording/playback error |
|
|
|
|
| EX33 |
| Sync target is recording alone |
|
|
|
|