18. Errors and Error Messages

18-2. Error Code

When the recording unit malfunctions during diagnostics, calibration, recording or playback operation, the error code is displayed on the LCD screen. Take the appropriate measure based on the table below.

When using the recorder in a dusty surrounding, the data could not be played back (or verified during recording) and also an error code is displayed. In such a case, perform a play back inside a room. If the error code does not disappear after the appropriate measure has been taken or if the displayed error code is not listed in this manual, contact service engineer.

-HDD-

EH03

0C01

Drive 1 write retries have exceeded the designated limit

 

 

0C02

Drive 2 write retries have exceeded the designated limit

 

 

1101

Drive 1 read retries have exceeded the designated limit

 

 

1102

Drive 2 read retries have exceeded the designated limit

 

 

3001

Drive 1 format is not correct

 

 

3002

Drive 2 format is not correct

 

 

 

 

 

EH04

0001

Hard disk not installed in drive 1

 

 

0002

Hard disk not installed in drive 2

 

 

4401

Drive 1 is faulty

 

 

4402

Drive 2 is faulty

 

 

 

 

 

EH90

0001

Formatting of drive 1 failed

 

 

0002

Formatting of drive 2 failed

 

 

 

 

 

EH91

 

No TOC found

 

 

 

 

 

EH92

 

An invalid TOC was detected.

 

 

 

 

 

EH93

 

Communication error occurred on HDD board

 

 

 

 

 

EH95

 

Error occurred in peripherals

 

 

 

File system error

 

 

 

IDE controller error

 

 

 

StarFabric control error

 

 

 

PCI control error

 

 

 

 

 

EH96

 

An unknown error occurred

 

 

 

 

-ADA-

EA20

00xx

A/D calibration error occurred. xx is the channel.

 

 

 

 

 

EA30

00xx

D/A calibration error occurred. xx is the channel.

 

 

 

 

 

EA60

 

ADA flash memory error

 

 

0001

CAL data was not found

 

 

0002

Unable to access

 

 

 

 

 

EA70

 

Measuring unit ID error

 

 

 

 

 

EA80

 

ADA board error

 

 

 

 

 

EA90

 

DMA timed out in REC

 

 

 

 

 

EA91

 

DMA timed out in PB

 

 

 

 

-Power Supply/

EP03

 

Power failure

Battery-

 

 

 

EP10

 

Battery voltage is low

 

 

 

 

 

 

-Communication-

Ed50

 

Communication error occurred between the IF board and ADA

 

 

 

board

 

 

 

 

 

Ed60

 

Communication error occurred between the DSP board and ADA

 

 

 

board

 

 

 

 

 

Ed70

 

Communication error occurred between the IF board and DSP

 

 

 

 

 

Ed80

 

Telnet communication error

 

 

 

 

 

ES30

 

Error occurred between DPR board and DR board

 

 

 

 

 

ES40

 

Error occurred between DPR board and IF board

 

 

 

 

 

ES50

 

Error occurred between DR board and IF board

 

 

 

 

-Synchronizing-

EX30

 

Sync Setting error/cable error

 

 

 

 

 

EX31

 

Sync No target/sync playback data

 

 

 

 

 

EX32

 

Sync Recording/playback error

 

 

 

 

 

EX33

 

Sync target is recording alone

 

 

 

 

18-2 (E)

SIR-3400H / SIR-3032i / SIR-3032W