BBasic Installation and Connections

Installing the Unit

Using the supplied screws, you can attach the camera to the ceiling or the wall.

Notes

If you attach the unit to the ceiling or the wall, entrust the installation to an experienced contractor or installer.

If you install the unit on the ceiling or the wall, be sure the ceiling or the wall is strong enough to withstand the weight of the camera. If the ceiling or the wall is not strong enough, the unit may fall and cause serious injury.

If you attach the unit to the ceiling or the wall, check periodically, at least once year, to ensure that the connection has not loosened. If conditions warrant, make this periodic check more frequently.

Take care not to stain or strike on the lens cover. Such acts may inhibit optimum performance of the camera and may cause a malfunction.

Before installation

After deciding the direction in which the camera will shoot, make the required holes for the connecting cables.

The lens of the camera is protected by a sheet for transport. Before installation, remove the lens cover, then remove the sheet.

Concrete wall: Use appropriate anchors, bolts and plugs (not supplied) for concrete walls.

Junction box: Use screws (not supplied) to match the holes on the junction box.

1Installing the Camera

1Remove the dome casing.

Loosen the three dome casing screws with the wrench supplied, and remove the dome casing.

2Remove the slit cover.

As shown in the figure below, loosen the two slit cover screws, and turn the slit cover to remove.

2

1

Mounting screws

3 Choose the conduit hole to use.

The supplied stand is provided with four

The BNC cables, 24V AC/12V DC

ø 4.5 mm (3/16 inch) mounting holes. Install

cable, I/O cable and audio cable are set

the stand to a ceiling or wall with screws

up to pass through the bottom conduit

through these holes.

hole at the factory. If you want to use the

The required mounting screws differ

side conduit hole, perform the following

depending on the installation location and its

steps 1 to 4.

material.

1Loosen the conduit hole plug screw

Steel wall or ceiling: Use M4 bolts (not

supplied) and nuts.

on the side conduit hole, and remove

Wood wall or ceiling: Use the supplied M4

the plug.

tapping screws. The panel thickness must be

2Disconnect the cables from the

15 mm (5/8 inch) or more.

connectors, and pull them out from

 

the bottom conduit hole.

GB 14 Installing the Unit