Periodic Sending (PS)

Select this check box to send images to the FTP server(s) periodically regardless of alarm output.

Setting example: To send images to the FTP server(s) every hour

Interval: Type the interval at which you want to send images to the FTP server(s) in the boxes. You can set the hour (H) between 0 and 168, the minutes (M) between 0 and 59, and the seconds between 0 and 55 in units of 5 seconds.

Image Size

Displays the size of the image to be sent to the FTP server(s). It is fixed to 360 × 243 for the SNC-VL10N, or 360 × 288 for the SNC-VL10P.

Naming Method

Set the form of naming the image file to be sent to the FTP server(s). Select the check box(es) you want to add to the file name.

Date & Time Suffix

Adds the date and time to the file name.

Alarm Sensor

Adds the alarm mode to the file name.

AD: if the image is sent at the time of an alarm triggered by the activity detection.

SI: if the image is sent at the time of an alarm triggered by the sensor input.

PS: if the image is sent by Periodic Sending.

SEQ suffix

Adds consecutive numbers, 000 to 999, to the file name. The number is reset to 000 when you click Apply on the FTP Setting page.

Manual Assigned Name

Type the file name up to 36 characters.

Suffix

Displays an extension “.eye.” The image is always sent in the Wavelet compressed format and “.eye” is added to its file name.

The example of a display

An example of the form you have set is displayed when you click Apply.

Apply/Cancel/Help

See “Buttons common to every setting page” on page 14.

Note

When the images are sent to the FTP server, the Frame Rate may not reach the set value depending on the network conditions and alarm frequency.

24 Sending Images to FTP Server at Alarm — FTP Setting Page