lighting equipment turns on when an EMG tally signal is output from pin 24 (OUTPUT 10).

Programming a remote commander

Commands that control the SRP-X500P functions can be stored to an optional programmable remote commander (RM-AV3000 series, etc.).

These functions are the following:

The AV/RGB SELECT buttons

The PROJECTOR POWER switch

The MASTER volume control

Turning up the volume

Turning down the volume

Muting of the volume

For details on how to program your remote commander, refer to the operation manual that was supplied with it.

1 Keep pressing the IR OUTPUT MODE button for 2 seconds or more.

The button lights up green and the remote emitter/ sensor lights up red when the SRP-X500P is ready to emit commands from the remote emitter/sensor. Note that no audio/video is output from the SRP- X500P during this time.

2 Operate the SRP-X500P function to be programmed to the remote commander as follows.

To program the function of the AV/RGB SELECT buttons

Press the AV/RGB SELECT button to be programmed to the remote commander so that it lights up.

To program the function of the PROJECTOR POWER switch

Press the PROJECTOR POWER switch so that it lights up.

To program the function for turning up the master volume

Rotate the MASTER control to the 11 o’clock position so that the MASTER MUTING indicator lights up.

To program the function for turning down the master volume

Rotate the MASTER control to the 9 o’clock position so that the MASTER MUTING indicator lights up.

To program the function for muting the master volume

Rotate the MASTER control to the position so that the MASTER MUTING indicator lights up.

3 Place the remote commander so that its top is pointed towards the remote emitter/sensor, and then ready the remote commander for programming commands from the SRP-X500P.

10 cm or less

Programmable remote commander

4 Press the IR OUTPUT MODE button.

The button and the remote emitter/sensor flash and command is output from the remote emitter/sensor.

5 When programming has completed, press the IR OUTPUT MODE button again.

The button lights up and the command output stops.

6 To program other functions, repeat this procedure from step 2.

7 Keep pressing the IR OUTPUT MODE button for 2 seconds or more.

The button and the remote emitter/sensor turn off and the SRP-X500P returns to normal status.

After programming has completed, be sure to verify that the command has been correctly programmed or not. If not, repeat the procedure from step 1.

28 Controls