3-5. White Balance Adjustment on Servicing

3-5-1. Signal Level Adjustment

3-5-2. White Balance Adjustment

1.Input the 80 IRE FLAT FIELD signal to INPUT-A.

(COMPONENT)

2.Warm up the unit at least 10 minutes.

3.Enter the Factory Mode (Please refer to 3-1-3)

Press the keys in the following order. “ENTER”“ENTER”N“ENTER”

The message “Do you wish to enter into the FACTORY MODE? Yes:No:” will be displayed.

Select “Yes:”. n

.When leaving the FACTORY MODE, perform item 3.

“Do you wish to return to the USER MODE?

Yes:No:” will be displayed. Select

“Yes:”.

.Cannot enter FACTORY MODE by MS channel.

4.Set the COLOR TEMP to MID mode.

5.Set the INPUT signal to the 80 IRE FLAT FIELD GREEN-only mode.

6.Change the CONTRAST: MAX to BRIGHT: MAX.

7.Measure the brightness (Ygmax).

8.Change CONTRAST: 80 to BRIGHT: 50.

9.Enter the P. DRV on the MENU screen by the DEV. ADJ.

10.Adjust the brightness to (0.65 Ygmax) by the VAMP/CONT (E) of P DRV.

11.Change the INPUT signal to 80 IRE FLAT FIELD white signal.

12.Change the CONTRAST: MAX to BRIGHT: MAX.

13.Measure the chromaticity (xmax, ymax)

14.Change CONTRAST: 80 to BRIGHT: 50.

15.Adjust the chromaticity to (xmax ±0.002, ymax ± 0.004) by the VAMP/SUB CON R(E) or SUB CON B (E) of P. DRV.

nput the 10 STEP signal to INPUT-A, and observe the chromaticity of each luminance.

When varying the chromaticity of each luminance, perform the following adjustments.

1) MID Mode of INPUT-A

1.Input the 100 IRE FLAT FIELD signal to INPUT-A

2.Measure the chromaticity (x, y)

3.Input the 80 IRE FLAT FIELD signal to INPUT-A.

4.Adjust the chromaticity (x, y) to the values measured in step 2, by the GAIN R and B of W/B MID mode.

5.Set the INPUT signal to the 30 IRE.

6.Adjust the chromaticity (x, y) to the values measured in step 2, by the BIAS R and B.

7.Repeat above steps 3. to 6. until the chromaticity become the following values.

x ±0.002, y ±0.004 (The x and y are the values measured in step 2.)

2) HIGH Mode of INPUT-A

1.Input the 80 IRE FLAT FIELD signal to INPUT-A.

2.Set the GAIN G to MID mode value at “_32” with the HIGH mode of the W/B. And set the GAIN R to MID mode value at “_23”.

3.Set the GAIN R and B that are equal to MID mode values. (Set the GAIN R and B to the same as MID mode values.)

4.Set the BIAS R, G and B that are equal to MID mode values. (Set the BIAS R, G and B to the same as MID mode values.)

5.Measure the chromaticity (x, y)

6.Input the 30 IRE signal to INPUT-A.

7.Adjust the chromaticity (x, y) to the values measured in step 2, by the BIAS R and B of W/B HIGH mode.

8.Input the 80 IRE signal to INPUT-A.

9.Adjust the chromaticity (x, y) to the values measured in step 2, by the GAIN R and B.

10.Repeat above steps 6. to 9. until the chromaticity become the following values.

x ±0.002, y ±0.004 (The x and y are the values measured in step 5.)

VPL-HS1

3-7

 

Page 55
Image 55
Sony VPLHS1FP White Balance Adjustment on Servicing, Signal Level Adjustment White Balance Adjustment, MID Mode of INPUT-A