Replacing the Lamp

2Open the lamp cover by loosening the screw with a Philips screwdriver.

The lamp used for the light source has a certain life. When the lamp dims, the color balance of the picture becomes strange, or “Please replace the LAMP.” appears on the screen, the lamp is exhausted. Replace the lamp with a new one (not supplied).

Use LMP-H150 Projector Lamp as the replacement lamp.

When replacing the lamp after using the projector

Turn off the projector, then unplug the power cord. Wait for at least an hour for the lamp to cool completely.

Caution

The lamp becomes a high temperature after turning off the projector with the [/1 (on/standby) switch. If you touch the lamp, you may scald your finger. When removing the lamp unit, make sure it remains horizontal, then pull straight up. Do not tilt the lamp unit. If you pull out the lamp unit while tilted and if the lamp is broken, the pieces may scatter, causing injury.

1Hold down the adjuster lock lever, slide it to the right, raise the rear of the projector, then return the adjuster lock lever. While keeping the screw on the bottom of the projector turned inward with a coin or a slotted screwdriver, open the projector cover with your hand.

Note

Be sure that the projector is stable.

3Loosen the screw on the lamp unit with a Philips screwdriver. Holding the handle, pull the lamp unit straight up.

4Insert the new lamp all the way in until it is securely in place. Tighten the screw, and fold down the handle.

Others

5Close the lamp cover and tighten the screw.

Replacing the Lamp 31 GB