Troubleshooting

 

 

 

Sound

 

 

 

 

 

Symptom

Cause

Remedy

No Sound.

A cable is disconnected or not connected

Check that the proper connections have been

 

properly.

made (see pages 15 (GB) to 18 (GB)).

 

 

 

There is no sound coming

SPEAKER in the SET SETTING menu

Set SPEAKER to ON if necessary (see page 27

through the external monitor.

has been set to OFF.

(GB)).

 

 

 

When inputting sound through

Monaural sound is being input through

Input stereo sound.

the AUDIO jack, sound comes

the AUDIO jack.

 

through one channel only.

 

 

 

 

 

 

 

 

Others

 

 

 

 

 

Symptom

Cause

Remedy

The LAMP/COVER indicator

The lamp cover or the air filter cover is

Attach the cover securely (see pages 32 (GB) and

flashes.

detached.

33 (GB)).

 

 

 

The LAMP/COVER indicator

The lamp has reached the end of its life.

Replace the lamp (see page 32 (GB)).

lights up.

 

 

The lamp has reached too a high

Wait for 90 seconds to cool down the lamp and

 

 

temperature.

turn on the power again (see page 20 (GB)).

 

 

 

The TEMP/FAN indicator

The fan is broken.

Consult with qualified Sony personnel.

flashes.

 

 

 

 

 

The TEMP/FAN indicator

The internal temperature is unusually

Check to see if nothing is blocking the ventilation

lights up.

high.

holes.

 

 

 

Both LAMP/COVER and

The electrical system has failed.

Consult with qualified Sony personnel.

TEMP/FAN indicators light up.

 

 

Warning messages

Use the list below to check the meaning of the messages displayed on the screen.

Message

Meaning

Remedy

High temp.!

Internal temperature is too high.

Turn off the power.

Lamp off in 1 min.

 

Check to see if something is blocking the

 

 

 

ventilation holes.

 

 

 

 

Frequency is out of range!

This input signal cannot be projected as

Input a signal that is within the frequency range.

 

 

the frequency is out of the acceptable

 

 

 

range of the projector.

 

 

 

 

 

 

 

The resolution setting of the output

Set the setting of output to XGA (see page 15

 

 

signal of the computer is too high.

(GB)).

 

 

 

Please check INPUT-A

You have input an RGB signal from the

Set INPUT-A correctly (see page 27 (GB)).

setting.

computer when INPUT-A in the SET

 

 

 

SETTING menu is set to COMPONENT

 

 

 

or VIDEO GBR.

 

 

 

 

Please replace the LAMP.

It is time to replace the lamp.

Replace the lamp.

 

 

 

 

Caution messages

Use the list below to check the meaning of the messages displayed on the screen.

Message

Meaning

Remedy

 

 

 

NO INPUT

No input signal

Check connections (see pages 15 (GB) to 18 (GB)).

 

 

 

Not applicable!

You have pressed the wrong key.

Press the appropriate key.

 

 

 

SPEAKER OFF

SPEAKER in the SET SETTING menu

Set SPEAKER to ON if necessary (see page 27

 

has been set to OFF.

(GB)).

 

 

 

35 (GB)