EVS Toolroom Lathes | E L E C T R I C A L | For Machines Mfg. Since 8/09 |
Additional Component Wiring
Spindle
RPM Sensor
Door Limit
Switch
Fig. 11. RPM sensor and door limit switch location.
Brake Limit
Switch
Fig. 12. Brake limit switch location.
Chuck
Guard Limit
Switch
Fig. 13. Chuck guard limit switch.
8
Work Light
| additional com- | |
| pontnet | |
Wt |
|
|
Bk 2 |
|
|
0 | Door Limit | |
| ||
| Switch, Figure 11. | |
|
| COMMON |
|
| ? |
|
| NO |
Bk | 0 | NC |
| 1X | |
Wt |
| |
Spindle RPM Sensor, Figure 11. | ||
| COM |
|
| KX | B |
| L |
|
Chuck Guard Limit Switch, Figure 13. | ||
| 3 |
|
9X | NC | NO |
| A | |
A1 | 4 | |
| NC | NO |
Brake Limit Switch, Figure 12.
5X | 14 | 13 |
A1 |
| @ |
|
| |
3 | 22 | 21 |
6
To Electrical
Box, Page 7.