Model SB1040/SB1041

P R E P A R A T I O N

For Machines Mfg. Since 8/09

SB1041 Circuit Requirements

This machine is prewired to operate on a 220V power supply circuit that has a verified ground and meets the following requirements:

Nominal Voltage

220V

Cycle

60 Hz

Phase

3-Phase

Circuit Rating

15 Amps

Plug/Receptacle Type

Hardwire

Grounding Requirements

In the event of certain types of malfunctions or breakdowns, grounding provides a path of least resistance for electric current—in order to reduce the risk of electric shock.

For 110V Connection (SB1040 Prewired)

This machine is equipped with a power cord that has an equipment-grounding wire and a grounding plug (similar to the figure below). The plug must only be inserted into a matching receptacle (outlet) that is properly installed and grounded in accordance with all local codes and ordinances.

GROUNDED

5-15 RECEPTACLE

Grounding Prong

5-15 PLUG

Current Carrying Prongs

Figure 1. NEMA 5-15 plug and receptacle.

For 220V 1-Phase Connection (SB1040)

Use the plug type listed in the Circuit Requirements for this voltage. The listed plug (similar to the figure below) has an equipment- grounding wire to safely ground the machine. The plug must only be inserted into a matching receptacle (outlet) that is properly installed and grounded in accordance with all local codes and ordinances.

GROUNDED

6-15 RECEPTACLE

Current Carrying Prongs

6-15 PLUG

Grounding Prong

Figure 2. NEMA 6-15 plug and receptacle.

For 220V 3-Phase Connection (SB1041)

Power supply connections that are hardwired to the power source must be connected to a grounded metal permanent wiring system, or to a system having an equipment-grounding conductor.

 

LOCKING

DISCONNECT SWITCH

Power Source

Machine

Conduit

Conduit

Ground

Ground

Figure 3. Typical hardwire setup.

Serious injury could occur if you connect the machine to power before completing the setup process. DO NOT connect to power until instructed later in this manual.