47

6.3.3.Select Sensor

Select sensor for setting.

Cameras Associated with Selected Sensor

Select the camera to be associated to the installed sensor. Multiple cameras can be connected to a single sensor. Activate sensor by clicking the desired sensor with the mouse. Then, select the camera number for the connecting sensor.

PTZ Preset

To set the Preset location of the camera, assign the number at the bottom of the camera.

External Output connected to each Sensor

When sensors detect any motion and are connected to a pre-selected alarm, the alarm can be automatically triggered. When there is intrusion, the sensor will be detected and the alarm output port will automatically halt. Select sensor and camera. Then, select the alarm output port to use. The connected alarm output port in the P series will be shown as activating and the chosen alarm output port will change to red color.

.

6.3.4.Sensor Type

Select the type of sensors to be preset on alarm from the N/C (Normal Close) or N/O (Normal Open). Only one type can be selected.

6.3.5.Sensor Recording Time

Sets the preset duration for recording time when a sensor is triggered. Maximum recording time is 5 minutes. When the preset recording time is up, the recording of images detected by sensors halt and the system returns to the previous recording mode until the sensor is triggered.

6.3.6.Use No.4 sensor for Auto Shutdown

In case the power supply fails, the Auto-Shutdown functions and the system shut down safely. The user can set up when the use the Auto-Shutdown (UPS battery backup time) during the discontinuous of power supply. Inquire from the place of purchase for the UPS used.

For example, when the UPS battery is set for 1 minute, the system shut down safely after power supply excess 1 minute.