11
(2) Status List
The following shows the content of status.
When there is the status code 20h there is no error. Anything other than 20h, it is recommended
to branch the error and processing.
Error notification codes may change or be added to without prior notice.
Undefined statuses are reserved for the system.
Code Status Content Rank
20h Normal
22h No target card (only when using a no card status command) C
23h No magnetic stripe (when inserted backward) or other error C
31h Parity Error B
32h No start code/end code B
33h LRC Error B
34h Erroneous character B
37h Magnetic stripe writing error B
38h Card jam B
40h Cover open B
41h Invalid command C
42h Cam motor error A
43h Erase head temperature error A
45h EEPROM error A
4Ch Non-compatible BMP file data C
51h Expand buffer overflow C
Rank A: Reader/writer hard error; inspection and repair are required.
Rank B: Device cleaning and card reissuing requiring operator. Depending on the frequenc y
of the error, it may be necessary to inspect and repair the reader/writer.
Rank C: Minor error or errors that can be easily recovered from that do not occur except
when debugging software. If these repeatedly occur, it may be necessary to inspect
and repair the reader/writer.
These ranks have been established based upon their potential to occur under
normal operating conditions.