18
(11) Reverse 7 bit format second track data setting command (Models: 300/310)
This command sets the write data to the second track with a reverse 7-bit format.
Excluding 02h (STX) and 03h (ETX), the write data string must be data from 01h to 7Eh in 0
to 69 bytes.
The starting and ending symbols, LRC and parity bit on the magnetic stripe are all
automatically applied. A reject response is issued when an error is detected in the write data.
* This command generates magnetic strip data that is in the direction opposite to the 7 bit
format second track data setting command 39h.
Command Transfer Formats
STX 36h Write data string ETX BCC
Response Transfer Formats
STX 36h Status ETX BCC