54
Specifying USB Serial Number
This command sets the terminal individual number when using a USB interface. If the serial
number is a value between 0 and 9, the host COM number can be value unique to that
terminal.
The COM port varies with the port to use when the serial number is 0.
STX, 90h, ‘U’/‘u’, to 1 digit parameters, ETX, BCC
Parameters are described in three digit decimal values.
The default serial number is ‘1’.
(3) Various setting commands
This command sets each of the default settings.
The setting is stored internally with the non-volatile memory, even when the power is cut.
When the power is turned on again, the stored contents are handled as the default
parameters.
Important
There is a limit to the number of times the non-volatile memory can be used.
Issuing this command is limited to when starting up the system, and frequent use should be
avoided.
Command Transfer Formats
ETX 91h Setting type Setting parameter ETX BCC
Response Transfer Formats
STX 91h Status ETX BCC