PRINCIPLES OF OPERATION
2-5. +5V Line Voltage Detector Circuit
The
R1
R2
1.25V
VCC
1
S∝A typ
–
+
3
GND
–
4
Cd
5
OUT
Fig. 2-14 Equivalent Circuit, Voltage Detection IC
Figure 2-15 shows the IC’s operational timing. The IC asserts a reset signal at its output terminal when the -5V line voltage falls below 4.25V, thereby resetting the CPU and the gate array.
VCC Voltage
4.25V |
|
0.8V | t |
|
Output
Voltage
td |
| td |
t td = 0.34 × Cd (pF) [∝s]
Fig. 2-15 Operation Timing Chart
– 22 –