Star Micronics Main Logic Board, Fuses TSP200-120/230, Parts Replacement, United Kingdom

Models: TSP200

1 72
Download 72 pages 39.47 Kb
Page 36
Image 36
6.Main Logic Board

PARTS REPLACEMENT

 

3

 

6

 

7 6

4

7

 

 

8

 

4

 

5

 

1

 

2

6.Main Logic Board

(1)Remove the upper case unit. (See 1. above.)

(2)Remove the connector cover 1.

(3)Remove the main chassis unit 3 from the lower casing unit 2.

(4)Remove:

Two tapping screws 4

Board chassis unit 5

Two tapping screws 6

Two screws 7

Connector

Main logic board 8

1

7.Fuses (TSP200-120/230)United Kingdom 2

7.Fuses (TSP200-120/230)

(1)Remove the main chassis unit from the lower casing unit. (See 5. above.)

(2)Check the fuses in the power unit.

Fuse F1 1

Fuse F2 2

If fuse is blown, replace it with the fuse type indicated below.

Destination

F1

F2

 

 

 

U.S.A.

5TT1A

5TT3A

 

 

 

EC

EAWK630mA

EAK3.15A

 

 

 

United Kingdom

EAWK630mA

5TT3A

 

 

 

If the replacement fuse also blows out, replace the power unit or check the main logic board.

– 32 –

Page 36
Image 36
Star Micronics technical manual Main Logic Board, Fuses TSP200-120/230, Parts Replacement, United Kingdom