Set the device to be a Telnet Client. In the case the Ethernet connected device is the Telnet server or other NETRS2321P in server mode.

IP Address

Depending on your selections above, there are one of three scenarios: TCP Server - Disabled

TCP Client - Remote Server Address UDP - Remote Target Address

Local Port

Assigns the local port for the device to listen on

TCP Server – Assigns the TCP server port number that the server will listen on TCP Client – Disabled

UDP – Assign the UDP port that this unit listens on

COM

Assign the desired virtual COM port number

Remote Port

TCP Server – Disabled

TCP Client – Assign the remote TCP port you wish to communicate on UDP – Assign the remote UDP port you wish to communicate on

Enable Control Connection (TCP Server or Client Only)

Enables/Disables control of the serial device on a remote network. Using the IP address and port number allows the user to gain control of the receiver from a remote location when this is enabled.

Second(s) for reconnection interval

Dictates the duration that the software will automatically attempt to reconnect the COM port to the serial port on the serial device server, for the purpose of keeping the connection alive.

Instruction Manual

16

Page 20
Image 20
StarTech.com NETRS2321P manual IP Address, Remote Port, Enable Control Connection TCP Server or Client Only