VENTING TABLES SUF 120 – 250

Maximum equivalent feet of intake and vent pipe using 3” PVC is 50 feet (15.2m). Equivalent feet must include any 90° elbows (two 45° elbows equal one 90° elbow). Three inch diameter 90° elbows are equivalent to 5' (1.5m) of pipe.

Maximum equivalent feet of intake and vent pipe using 4” PVC is 120 feet (36.6m). Equivalent feet must include any 90° elbows (two 45° elbows equal one 90° elbow). Four inch diameter 90° elbows are equivalent to 5' (1.5m) of pipe.

Vent Length Table Equivalent Feet (Meters) 120 through 250

Number of 90°

3" Minimum

3" Maximum

4"Maximum

Elbows

Pipe (Ft./M.)

Pipe (Ft./M.)

Pipe (Ft./M.)

 

 

 

 

ONE (1)

7/2.1

45/13.7

115/35

 

 

 

 

TWO (2)

7/2.1

40/12.2

110/33.5

 

 

 

 

THREE (3)

7/2.1

35/10.7

105/32

 

 

 

 

FOUR (4)

7/2.1

30/9.1

100/30.5

 

 

 

 

FIVE (5)

7/2.1

---

95/29

 

 

 

 

SIX (6)

7/2.1

---

90/27.4

 

 

 

 

VENTING TABLES SUF 300,400,

Vent Length Table Equivalent Feet (Meters) 300,400,

Number of

4" PVC

90°Elbows

Maximum Feet / meters of Pipe

 

 

ONE (1)

65' / 19.7 m

 

 

TWO (2)

60' / 18.2 m

 

 

THREE (3)

55' / 16.7 m

 

 

FOUR (4)

50' / 15.2 m

 

 

FIVE (5)

45' / 13.6 m

 

 

SIX (6)

40' / 12.1 m

 

 