ULTRAFORCE COMMERCIAL GAS WATER HEATER

SUF 120 thru 400 SERVICE HANDBOOK

CONTROLS – PRESSURE SWITCHES – SUF 120 through 250

BLOCKED INLET

PRESSURE SWITCH

MODEL PRESSURE

All0.85”WC

Norm ally Clos e d / Ope n on a Ris e in Pres s ure

Tolerance +/-.05”WC

LOW GAS PRESSURE

 

SWITCH

MODEL

PRESSURE

Natural

4.0”WC

LP

8.0”WC

Norm ally Ope n / Clos e on a Ris e in Pre s s ure Tole rance +/-.05”WC

BLOCKED OUTLET PRESSURE SWITCH

MODEL SWITCH

120N+1.2”WC

150N +0.98”WC

199N +1.06”WC

250N +4.0”WC

120LP +1.3”WC

150LP +1.3”WC

199LP +4.0”WC

250LP +2.0”WC

Norm ally Clos e d / Ope n on a Rise in Pres s ure Tolerance +/-.05”WC

BLOWER PROVER

PRESSURE SWITCH

 

 

MODEL

PRESSURE

 

 

 

All

+.075”WC

 

 

 

 

 

 

 

 

 

 

Norm ally Ope n / Clos e on a Ris e in Pre s s ure Tole rance +/-.05”WC

Top View of Pressure Switches

Note: Check the website www.statewaterheaters.com for Technical Bulletin S023-06 “Air Pressure Switches” under “Literature/Service Handbooks”

State Water Heaters – Technical Training Department 28

Ashland City, Tennessee © 2009

Servicing should only be performed by a Qualified Service Agent

198152-002

Page 29
Image 29
State Industries SUF100150, SUF100199 manual Top View of Pressure Switches