ULTRAFORCE COMMERCIAL GAS WATER HEATER

SUF 120 thru 400 SERVICE HANDBOOK

HOT SURFACE IGNITER / FLAME SENSOR / CONTROL TIMING

HOT SURFACE IGNITER

This water i s equipped with an electric hot surface i gniter. The i gniter m aterial i s silicone carbide and should not be handled with bare hands because of possible damage to the igniter.

The normal ohm reading at 77°F is listed between 40 and 70 ohms. The minimum igniter current monitored by the CCB is 2.7 amps. Once this threshold is met a check mark will appear by the igniter i con i n the UIM (display).

CONTROL TIMING

Pre-purge

25 seconds

 

 

Igniter Warm-up

17 seconds

 

 

Trial for ignition

5 seconds

Gas Control Open

 

 

 

Inter/Post Purge

30 seconds

 

 

FLAME SENSOR

This water hea ter is eq uipped w ith an electronic flame sensor. The flame sensor senses fl ame by passi ng a s mall electric current through the burner flame. This type of f lame s ensing is al so k nown a s fl ame rectification. T he CCB is l ooking fo r a minimum current of .7 micro amperes for the water heater to operate. Once this current is established the UIM will display a flame icon.

State Water Heaters – Technical Training Department 31

Ashland City, Tennessee © 2009

Servicing should only be performed by a Qualified Service Agent

198152-002