State Industries SUF100150, SUF100199 manual Blower Speed Control SUF 199, Model

Models: SUF100199 SUF100150

1 38
Download 38 pages 13.09 Kb
Page 33
Image 33

ULTRAFORCE COMMERCIAL GAS WATER HEATER

SUF 120 thru 400 SERVICE HANDBOOK

BLOWER SPEED CONTROL SUF 199 AND 250

The input of the SUF 199 and SUF 250 is determined by the blower. The input of the water heater may be determined by clocking the meter as shown on page 5 or by making sure the blower i s receiving the proper Hz signal. The blower rpm is controlled by the Central Control Board (CCB). The signal to the blower may be measured by attaching a MULTIMETER that has a Hertz (Hz) setting as shown in the illustration to the right. If the Hz signal is within +/

Meter black lead is connected to ground (not shown) and the red lead is connected to an open te rminal o n bl ower spee d con trol connection.

Model

Hz

Hz

 

 

 

199 N

133

87

 

 

 

250 N

133

87

 

 

 

199 LP

200

156

 

 

 

250 LP

266

96

 

 

 

Note: R emoving the plug show n in the illustration will cause the blower to accelerate and the input of the water heater to increase to a much higher rate.

Meter red probe

connected to

open terminal on

plug

State Water Heaters – Technical Training Department 32

Ashland City, Tennessee © 2009

Servicing should only be performed by a Qualified Service Agent

198152-002

Page 33
Image 33