ULTRAFORCE COMMERCIAL GAS WATER HEATER

SUF 120 thru 400 SERVICE HANDBOOK

CONTROLS – CONNECTIONS, IGNITER, FLAME SENSOR, SIGHT GLASS, POWERED ANODES

The connections for the hot surface igniter and the flame sense rod are shown below. Also shown is the burner sight glass. These features are typical for all models.

The new U ltra Force com mercial w ater heater i s eq uipped w ith pow ered an odes. These anodes never need replacement. The CCB monitors the cur rent th rough t he anodes and will declare a fault if there is a disconnected wire or if there is no water in the tank.

Flame

Sensor

Hot Surface Igniter

Burner Mounting

Bolts

Burner Sight Glass

Powered anode connection

State Water Heaters – Technical Training Department 30

Ashland City, Tennessee © 2009

Servicing should only be performed by a Qualified Service Agent

198152-002

Page 31
Image 31
State Industries SUF100150, SUF100199 manual Ultraforce Commercial GAS Water Heater