2.2SHIPMENT AND TRANSIT
NOTE
For Air Cooled Unit Only.
The freezer has been assembled, operated and inspected at the factory. Upon arrival at the final destination, the freezer must be checked for any damage that may have occurred during transit.
With the method of packaging used, the freezer should arrive in excellent condition. THE CARRIER IS RESPONSIBLE FOR ALL DAMAGE IN TRANSIT, WHETHER VISIBLE OR CONCEALED. Do not pay the freight bill until the freezerhasbeenchecked fordamage. Have the carrier note any visible damage on the freight bill. If concealed damage and/or shortage are found later, advise the carrier within 10 days and request inspection. The customer must place claim for damages and /or shortages in shipment with the carrier. Stoelting,
Inc. cannot make any claims against the carrier.
2.3FREEZER INSTALLATION
CAUTION
FAILURE TO INSTALL THE FREEZER WITHIN RECOMMENDED LIMITS WILL RESULT IN POOR PERFORMANCE OF THE SYSTEM, PREMATURE COMPONENT FAILURE AND CANCELLATION OF WARRANTY.
Installation of the freezer involves moving the unit close to its permanent location, removing all protective packaging, setting in place and cleaning.
CAUTION
REMOVE LOWER FRONT PANEL BEFORE REMOVING FREEZER FROM SKID.
A.The freezer requires adequate ventilation.A minimum of 3” (7.6 cm) of vent space is required for free flow of cooling air at the front and back (Fig. 4).
A rear
1.Remove both back panel mounting screws below the bottom most louver.
2.Attach rear
ÅBottom Most Louver Of Back Panel
ÅBack Panel Mounting Screw
Ç
Rear Blockoff Panel
A
CAUTION
FLUSH ALL WATER LINES BEFORE INSTALLATION. IN NEW STORES WITH SEDIMENT WATER, ADD SUITABLE FILTER OR STRAINER TO WATER INLET.
CAUTION
FAILURE TO PROVIDE ADEQUATE VENTILATION WILL VOID WARRANTY.
B.The unit is shipped without casters installed. To install the casters, lift and support the unit while screwing the four casters into the bottom of the frame at each corner.
Figure 4. Space and Ventilation Requirements
4