2.2SHIPMENT AND TRANSIT

NOTE

For Air Cooled Unit Only.

The freezer has been assembled, operated and inspected at the factory. Upon arrival at the final destination, the freezer must be checked for any damage that may have occurred during transit.

With the method of packaging used, the freezer should arrive in excellent condition. THE CARRIER IS RESPONSIBLE FOR ALL DAMAGE IN TRANSIT, WHETHER VISIBLE OR CONCEALED. Do not pay the freight bill until the freezerhasbeenchecked fordamage. Have the carrier note any visible damage on the freight bill. If concealed damage and/or shortage are found later, advise the carrier within 10 days and request inspection. The customer must place claim for damages and /or shortages in shipment with the carrier. Stoelting,

Inc. cannot make any claims against the carrier.

2.3FREEZER INSTALLATION

CAUTION

FAILURE TO INSTALL THE FREEZER WITHIN RECOMMENDED LIMITS WILL RESULT IN POOR PERFORMANCE OF THE SYSTEM, PREMATURE COMPONENT FAILURE AND CANCELLATION OF WARRANTY.

Installation of the freezer involves moving the unit close to its permanent location, removing all protective packaging, setting in place and cleaning.

CAUTION

REMOVE LOWER FRONT PANEL BEFORE REMOVING FREEZER FROM SKID.

A.The freezer requires adequate ventilation.A minimum of 3” (7.6 cm) of vent space is required for free flow of cooling air at the front and back (Fig. 4).

A rear block-off panel has been provided to prevent recirculation of hot air beneath the freezer. The rear block-off panel maximizes the efficiency of the freezer. See the illustration for the installation instructions.

1.Remove both back panel mounting screws below the bottom most louver.

2.Attach rear block-off panel to the back panel using the same screws as shown.

ÅBottom Most Louver Of Back Panel

ÅBack Panel Mounting Screw

Ç

Rear Blockoff Panel

A water-cooled freezer requires an adequate water supply, install 3/8 inch pipe or ½ inch inside diameter copper water line to each side of the freezer. Connect water outlet to a drain using a ½ inch inside diameter line. Automatic washer hoses work well for final connections. All water connections must comply with local codes.

CAUTION

FLUSH ALL WATER LINES BEFORE INSTALLATION. IN NEW STORES WITH SEDIMENT WATER, ADD SUITABLE FILTER OR STRAINER TO WATER INLET.

CAUTION

FAILURE TO PROVIDE ADEQUATE VENTILATION WILL VOID WARRANTY.

B.The unit is shipped without casters installed. To install the casters, lift and support the unit while screwing the four casters into the bottom of the frame at each corner.

Figure 4. Space and Ventilation Requirements

4