A.SPIGOT SWITCH

When the spigot handle is opened the SPIGOT switch will start the auger drive motor and refrigeration systems. When the spigot handle is closed, the auger drive motor and compressor will remain on until the product in the barrel reaches the proper consistency.

B.CLEAN-OFF-SERVE SWITCH

The CLEAN-OFF-SERVE switch is a three-position rocker switch used to control the operation of the refrigeration system and auger. When the switch is placed in the CLEAN position, the refrigeration system will be off and the auger will rotate for cleaning.

When the switch is placed in the OFF position, the refrigeration system and auger will not operate.

When the switch is placed in the SERVE position, the refrigeration system and auger will operate automatically. The switch should be placed in the ON position for normal operation.

C.PUSH TO FREEZE SWITCH

The illuminating PUSH TO FREEZE switch is used to start the freezing cycle. During the initial freeze down, the CLEAN-OFF-SERVE rocker switch is placed in the SERVE position. Then the PUSH TO FREEZE switch is pressed until the drive motor and compressor comes “ON.”

NOTE

After the gearmotor starts, there is a 3-second delay before the compressor starts.

During the normal operation, the red PUSH TO FREEZE switch will illuminate after the freezer has been in idle for the pre-set time. Before drawing product, press the red PUSH TO FREEZE switch if it is illuminated. Wait until the green lens is illuminated before dispensing.

NOTE

If the freezer shuts off and the PUSH TO FREEZE light flashes, you have an error condition. Turn the CLEAN-OFF-SERVE switch to the OFF position, correct the problem and turn the freezer back on.

GREEN LIGHT

The green lens is used to indicate that the product has reached the proper consistency and is ready to be dispensed.

NOTE

If the PUSH TO FREEZE lens is illuminated, push the PUSH TO FREEZE switch and wait until the green lens illuminates before dispensing.

MIX LOW LIGHT

The MIX LOW light is used to indicate when the hopper is low on mix. When the light is illuminated fill the hopper with mix.

CAUTION

FAILURE TO REFILL HOPPER IMMEDIATELY MAY RESULT IN OPERATIONAL PROBLEMS.D.DISPENSE RATE ADJUSTER

The dispense rate adjuster limits the opening of the spigot.

To adjust product dispense rate, turn the adjusting knob clockwise for slower flow and counterclockwise for faster flow.

E.DOOR INTERLOCK SWITCH

When the door is securely fastened the freezer will operate normally. When the door is removed, the drive and compressor will not run.