When the spigot handle is opened the SPIGOT switch will start the auger drive motor and refrigeration systems. When the spigot handle is closed, the auger drive motor and compressor will remain on until the product in the barrel reaches the proper consistency.
B.The
When the switch is placed in the OFF position, the refrigeration system and auger will not operate.
When the switch is placed in the SERVE position, the refrigeration system and auger will operate automatically. The switch should be placed in the ON position for normal operation.
C.PUSH TO FREEZE SWITCHThe illuminating PUSH TO FREEZE switch is used to start the freezing cycle. During the initial freeze down, the
NOTE
After the gearmotor starts, there is a
During the normal operation, the red PUSH TO FREEZE switch will illuminate after the freezer has been in idle for the
NOTE
If the freezer shuts off and the PUSH TO FREEZE light flashes, you have an error condition. Turn the
The green lens is used to indicate that the product has reached the proper consistency and is ready to be dispensed.
NOTE
If the PUSH TO FREEZE lens is illuminated, push the PUSH TO FREEZE switch and wait until the green lens illuminates before dispensing.
MIX LOW LIGHTThe MIX LOW light is used to indicate when the hopper is low on mix. When the light is illuminated fill the hopper with mix.
CAUTION
FAILURE TO REFILL HOPPER IMMEDIATELY MAY RESULT IN OPERATIONAL PROBLEMS.D.DISPENSE RATE ADJUSTERThe dispense rate adjuster limits the opening of the spigot.
To adjust product dispense rate, turn the adjusting knob clockwise for slower flow and counterclockwise for faster flow.
E.DOOR INTERLOCK SWITCHWhen the door is securely fastened the freezer will operate normally. When the door is removed, the drive and compressor will not run.