Low overrun

1.

Mix inlet regulator (carburetor) missing.

 

2.

Mix inlet regulator (carburetor) “O” Ring

 

 

missing.

 

3.

Mix inlet regulator (carburetor) air tube

 

 

blocked.

1.Replace mix inlet regulator (carburetor).

2.Replace mix inlet regulator (carburetor) “O” Ring.

3.Clean with sanitizer brush.

Front door leaks.

1.

Front door knobs are loose.

1.

Tighten knobs.

 

2.

Spigot parts are not lubricated.

2.

See paragraph 3.11.

 

3.

Chipped or worn spigot “O” Rings.

3.

Replace “O” Rings.

 

4.

“O” Rings or spigot installed wrong.

4.

Remove spigot and check “O” Rings.

 

5.

Spigot hole in front door nicked or

5.

Replace front door.

 

 

scratched.

 

 

Hopper will not

1. EPR valve needs to be adjusted.

1.

(See note 1.)

Maintain mix

2.

Temperature control failure.

2.

Replace. (See notes 1 or 2.)

temperature below

3.

Refrigeration problem.

3.

Check system. (See note 1.)

45°F (7°C).

 

 

 

 

1.Must be performed by a qualified service person.

2.The local dealer, distributor or Stoelting, LLC, Service Department should be contacted. Write or call:

Stoelting, LLC 502 Hwy. 67, Kiel, WI 53042

Phone (920) 894-2293.

20