C. For location of proper electrical connections, refer to Figure 7.
Figure 5. Leveling Freezer
C.Accurate leveling is necessary for correct drainage of freezer barrel to insure correct
Figure 6. Caster Adjustment
Figure 7. Connecting Permanent Wiring
NOTE
When supply voltage is less than 218V, reconnect transformer. Switch orange and red wires from transformer at the terminal strip and cap blue wire.
D. Please read decal located on lower electrical box cover (Fig. 8)
2.4ELECTRICAL CONNECTIONS
WARNING
BEFORE INSTALLATION OF ANY CABLE IN THE FREEZER, DISCONNECT THE FREEZER FROM ITS ELECTRICAL SUPPLY SOURCE.
CAUTION
ROUTE ELECTRICAL CABLE SO THAT IT CANNOT BE ACCIDENTALLY DAMAGED BY PINCHING, CRUSHING, ETC.
A.Connect freezer to a properly grounded 208/230 volt (AC), source of electricity.
B.To access the electrical boxes, remove the two Phillips head screws on the left and right side panels. Then pull the panel down and out.
Figure 8. Danger Decal
The model 4231 freezer is two individual freezers in a common enclosure. EACH SIDE MUST BE
CONNECTED INDIVIDUALLY. EACH SIDE MUST HAVEITSOWNELECTRICALSUPPLY. Whenmaking the electrical supply connections, YOU MUST
MAINTAIN STRAIGHT POLARITY FROM SIDE TO SIDE.
E.Check the auger shaft rotation by placing the MAIN DRIVE switch in the CLEAN position. Auger shaft rotation is clockwise as viewed through the clear plastic front door. If the rotation is not clockwise, turn the main electrical power OFF. Then reverse L1 and L3 electrical power lines to the junction box (three phase only).
5