INSTALLATION INSTRUCTIONS
INSTALLATION
6.lighting the NEMOS
6.1Locate the control valve on the appliance. There are two control knobs on the valve, the right hand knob controls the pilot ignition and the left hand knob controls the main burner.
6.2If your appliance has already been upgraded to battery remote control, please refer to the instructions provided with the upgrade to operate the remote control. The following instructions will work for either situation.
6.3Ensure that the left hand control knob is pointing to off ().
6.4Ensure that the right hand control knob is pointing to off ().
6.5Press in the right hand control knob and rotate it anti- clockwise until a click is heard (keep pressing in) and the knob is pointing to pilot (). The pilot should now light. If the pilot has not lit, repeat the procedure until it does.
6.6Keep the control knob pressed for 10 seconds and then release it, the pilot should stay alight. If the pilot goes out, repeat the procedures until it does.
6.7If the pilot will not light after repeated attempts, contact the retailer or installer from whom the appliance was purchased.
6.8Turn the right hand control to point to main burner ( ). The appliance can now be controlled using the left hand control knob.
6.9Turn the left hand control knob to point to low fire ( ),
the main burner will light on low. The burner can now be controlled between low and high settings. Turn the control knob anticlockwise to increase the flame height and clockwise to decrease the flame height.
THE YELLOW FLAMES WILL APPEAR WHEN THE FIRE HAS
GAINED SUFFICIENT HEAT - TYPICALLY 10 TO 20 MINUTES.
7.COMMISSIONING
7.1Check all ceramics, door etc.
7.2Check flame picture.
7.3Check gas pressure.
18