Stovax 8627 MA manual User Instructions, flame failure device, running in, servicing, ventilation

Models: 8627 MA P8627 MA P8627 BS 8627 BS

1 28
Download 28 pages 6.09 Kb
Page 7
Image 7
AR1120

USER INSTRUCTIONS

10

AR1120

6.9Ensure that the fibreglass seal on the back of the glass frame is intact then hook the location tabs over the hooks on the top of the firebox. Replace the nine screws working from the top down. Tighten the screws evenly. DO NOT OVER TIGHTEN. See diagram 2, section 5 "Cleaning the Nemos"

NEVER OPERATE THE APPLIANCE WHEN THE GLASS PANEL IS REMOVED OR BROKEN.

6.10Close the door by pushing shut centrally on the RH side.

NOTE: ENSURE THAT THE LOGS ARE POSITIONED AS ABOVE. ONLY USE THE CORRECT AMOUNT OF LOGS AS SPECIFIED IN THE DIAGRAMS.

7.flame failure device

7.1This is a safety feature incorporated on this appliance which automatically switches off the gas supply if the pilot goes out and fails to heat the thermocouple.

8.running in

8.1The surface coating on the logs used in your GAZCO fire will "burn off" during the first few hours of use producing a harmless and temporary odour. This will disappear after a short period of use. If the odour persists, ask your installer for advice.

9.servicing

9.1The fire must be serviced every 12 months by a qualified Gas Engineer. In all correspondence always quote the Model number and the Serial number which may be found on the databadge.

10.ventilation

10.1 This appliance requires no additional ventilation.

11.installation details

11.1To assist in any future correspondence, your installer should have completed the commissioning sheet at the front of this book, this records the essential installation details of the appliance. In all correspondence always quote the Model number and Serial number.

12.HOT SURFACES

12.1Parts of this appliance become hot during normal use. It is therefore recommended that a suitable fire guard be used for protection of young children and the infirm. Indeed, all parts of the appliance should be treated as a 'working surface' except for the control access panel.

7