Stovax 8627 MA Installation Instructions, Site Requirements, TOP FLUE VERTICAL KIT 8524/8524AN

Models: 8627 MA P8627 MA P8627 BS 8627 BS

1 28
Download 28 pages 6.09 Kb
Page 11
Image 11
2.3 TOP FLUE VERTICAL KIT (8524/8524AN)

INSTALLATION INSTRUCTIONS

SITE REQUIREMENTS

2.3 TOP FLUE VERTICAL KIT (8524/8524AN)

Vertical from the top of the appliance (See Diagram 1C).

A minimum vertical rise 3m (9’10") to a maximum 10m (32’10"). The basic kit comprises:

2 x 1m lengths

1 x 1m terminal length

1 x 52mm restrictor

1 x 47mm restrictor

Extra lengths may be added from the list below.

2.4 TOP FLUE VERTICAL OFFSET KIT (8530)

Used with kit 8524 only (See diagram 5)

A minimum rise of 500mm (191/2˝) is required to the first bend. Refer to diagram 4.

2.5 OPTIONAL FLUE LENGTHS & BENDS

All flue components are 150mm diameter (6")

Nominal
Actual Length
Stainless
Anthracite
Length

 

Finish

Finish

 

 

 

 

200mm

140mm

8527

8527AN

500mm

440mm

8528

8528AN

 

 

 

 

1000mm

940mm

8529

8529AN

 

 

 

 

40° Bend

N/A

8507

8507AN

90° Bend

N/A

8508

8508AN

3.GAS SUPPLY

3.1Before installation, ensure that the local distribution conditions (identification of the type of gas and pressure) and the adjustment of the appliance are compatible.

3.2Ensure that the gas supply is capable of delivering the required amount of gas and is in accordance with the rules in force.

3.3Soft copper tubing can be used to install the appliance. Soft soldered joints can be used externally of the appliance.

3.4The appliance is supplied complete with a factory fitted isolation device incorporated into the inlet connection, no further isolation device is required.

3.5All supply gas pipes must be purged of any debris that may have entered, prior to connection to the appliance.

3.6The gas supply may enter through the floor directly under the appliance or through the knockout panel in the rear RH corner of the outer casing. In both instances, the front lower panel is removable to aid connection of the gas supply and a preformed pipe is factory fitted to make connection to the main inlet isolation device easier.

4.VENTILATION

4.1This appliance requires no additional ventilation.

5.APPLIANCE LOCATION

5.1It is not necessary to site the appliance on a non- combustible floor. However, for practical reasons, the floor should be flat and solid to allow the appliance to be levelled and secured in place.

5.2This appliance may be situated anywhere in the room but due consideration should be taken to ensure that it is sited within the constraints of the allowable flue configuration.

5.3If the appliance is to be sited against a combustible wall, a clearance of 50mm should be allowed between the wall and the rear of the appliance.