![THERMOSTATIC REMOTE CONTROL](/images/new-backgrounds/38513/3851327x1.webp)
INSTALLATION INSTRUCTIONS
INSTALLATION
2.15Replace the glass frame; ensure the top of the frame is hooked on the tabs at the top of the appliance and replace the nine screws with the three longest screws used in the bottom fixing holes. Tighten from the top down.
HAVE YOU PURGED THE GAS SUPPLY?
2.16Connect the gas supply to the isolation device using 8mm pipe. Connect a suitable pressure gauge to the test point and turn on the gas supply and check for leaks.
2.17Light the appliance and set it to maximum. Check the pressure corresponds to the data badge. Turn the gas off and replace the test point screw. Turn the gas on and check the screw for leaks.
THE YELLOW FLAMES WILL APPEAR WHEN THE FIRE HAS GAINED SUFFICIENT HEAT - TYPICALLY 20 MINUTES.
3.LIGHTING THE LINEA
Note: The Emergency Shut Off switch must be in the ON
position, refer to Section 2, User Instructions. There are two ways of lighting the Linea:
•by thermostatic remote control
•using the fire’s touchpad
THERMOSTATIC REMOTE CONTROL
9
AR1883
This remote controls the gas fire. In ‘MANUAL MODE’ you can:
•turn on the main burner
•regulate the flame from low to high and back
•turn off the burner
In ‘TEMP MODE’ you can:
•set the room temperature so the fire automatically maintains that temperature
In ‘TIMER MODE’ the fire:
• turns on and off according to the set time periods
•automatically regulates the room temperature during the set periods
TOUCH PAD CONTROL
10
AR1885
•Press the
30 seconds)
•Press the UP button to increase the flame height
•Press the DOWN button to decrease the flame height. At the lowest point it goes to ‘standby mode’, (only pilot
lit)
•Press the
4.REPROGRAMMING HANDSET/CONTROL BOX
•Remove the battery cover from the handset to see the four DIP switches, Diagram 11
11
AR1935
14