USER INSTRUCTIONS
1.general
1.1A competent person must carry out installation and servicing.
1.2In all correspondence, please quote the appliance type and serial number, which can be found on the data badge located on a plate under the control valve.
1.3Ensure that curtains are not positioned above the appliance and there is at least 300mm between the sides of the appliance and any curtains.
1.4If any cracks appear in the glass panel do not use the appliance until the panel has been replaced.
1.5If, for any reason, the flue has to be removed from the appliance, the seals must be replaced in the inner spigot.
1.6Do not obstruct the flue terminal in any way, i.e. by planting flowers, trees, shrubs etc in the near vicinity, or by leaning objects up against the terminal guard.
1.7Do not use a garden sprinkler or hose near the terminal.
1.8Do not stand or place objects on the terminal guard as this will deform it.
This product is guaranteed for 2 years from the date of installation, as set out in the terms and conditions of sale between Gazco and your local Gazco dealer. Please consult with your local Gazco dealer if you have any questions. In all correspondence always quote the Model Number and Serial Number.
2. lighting the LINEA
There are two ways of lighting the Linea:
•by thermostatic remote control, see 2A
•using the fire’s touch pad, see 2B
2A - THERMOSTATIC and TIMER REMOTE CONTROL
1
AR1883
Turning the Linea On
Your remote can control the gas fire from pilot ignition through to shut down.
To turn the fire on:
• Press the OFF button and the UP arrow simultaneously
The pilot and main burner ignite and the remote is now in Manual Mode. In ‘MANUAL MODE’ you can:
•turn on the main burner
•regulate the flame from low to high and back
•turn off the burner leaving just the pilot burning In ‘TEMP MODE’ you can:
•set the room temperature so the thermostat in the remote automatically maintains that temperature
In ‘TIMER MODE’ the fire:
•turns on and off according to the set time periods
•automatically regulates the room temperature during the set periods
NOTE: When operating the fire in Temp or Timer mode, the pilot remains lit and the fire then automatically switches on at programmed times to bring the room to the set temperature whether or not you are in the room.
NEVER LEAVE ANY COMBUSTIBLE MATERIALS WITHIN 1 METRE OF THE FRONT OF THE APPLIANCE.
2.1 SWITCHING BETWEEN MODES
• | Press the SET button to change to Manual Operation | |
• | Press again to change to Temperature Mode | |
• | Keep pressing to run through all operating modes. These | |
| are: |
|
| • | MAN |
| • | DAY TEMP |
| • | NIGHT TEMP |
| • | TIMER |
|
| and back to MAN |
NOTE: MAN mode can also be reached by pressing either the UP or DOWN arrow
2.2MAN MODE
•Press both the UP arrow and immediately press the OFF button to light the appliance. You hear a click as the fire begins the ignition process , (up to 30 seconds)
•Press the OFF button to turn the appliance off
INCREASING TEMPERATURE
•Press the UP arrow once to increase flame height one stage
•Press and hold the UP arrow to increase to maximum
DECREASING TEMPERATURE
•Press the DOWN arrow once to decrease flame height one stage
•Press and hold the DOWN arrow to decrease to minimum
At the lowest point the fire goes to ‘standby mode’ (only pilot lit)
NOTE: While pressing a button a symbol indicating transmission appears on the display. The receiver confirms transmission with an acoustic signal.
4