Stovax PR0731 manual User Instructions, 2B TOUCH PAD CONTROL

Models: PR0731

1 26
Download 26 pages 20.52 Kb
Page 5
Image 5
2B TOUCH PAD CONTROL

USER INSTRUCTIONS

Turning the Linea Off

Press the Off button to extinguish the pilot

2.3TEMP MODE

The display shows the current room temperature.

To increase or decrease the fire’s output:

Press the SET button to select either the DAY TEMP or the NIGHT TEMP mode by briefly pressing the SET button

Hold the SET button until the TEMP display flashes and then let go

Set the desired temperature with the UP and DOWN arrows. (Minimum temperature 5C, maximum 30C or

fahrenheit)

Press the OFF button to stop the display flashing or wait to return to TEMP mode.

NOTE: If you set a temperature that is beneath the current room temperature, the fire automatically switches to OFF.

NOTE: If you would like the Night temperature control to turn off then decrease the temperature until [---] is displayed.

2.4TIMER MODE

There are two programmable settings you can make over a 24 hour period, P1 and P2

P1 + Manual background = Start Timed Setting 1

P1 + Manual background = End of Timed Setting 1

P2 + Manual background = Start Timed Setting 2

P2 + Manual background = End of Timed Setting 2

2.4.1P1 - Program 1 for a Timed Setting

Press the SET button until the TIMER mode is displayed

Hold the SET button. The displays flashes the current time for P1. While the time displayed is flashing you can alter the hours and minutes set.

To set the time your fire first lights, change the Start Timed Setting for P1Manual background .

Press the UP arrow to alter the hour

Press the DOWN arrow to alter the minutes in 10 minute increments

Press SET again to move to the End of Timed Setting,

P1. The display shows the current setting for P1 Manual background This is the time your Linea first shuts down:

Press the UP arrow to alter the hour

Press the DOWN arrow to alter the minutes

2.4.2P2 - Program 2 for a Timed Setting

Use the same steps outlined in 2.4.1 to change the setting for P2.

If you have already set P1 and want to alter the setting for

P2 only:

Press the SET button until TIMER mode is displayed

Hold the SET button until the display flashes the current time for P1Manual background

Press the SET button again to scroll past the settings for

P1Manual background and P1 Manual background

With the time still flashing:

Press the UP arrow to alter the hour

Press the DOWN arrow to alter the minutes

Once all four times are set press the OFF button or simply wait to complete programming.

2.5LOW BATTERY

“BATT” is displayed on the remote when its batteries need replacement.

2.6SETTING THE TIME

Simultaneously press the up and down arrow buttons

Press the up arrow to set the hour and the down arrow to set the minutes

Press OFF to return to the manual mode or simply wait

2.7SETTING THE °C/24 HOUR OR °F/12 HOUR CLOCK

Press OFF and the down arrow until the display changes from °C/24 hour clock to °F/12 hour clock and vice versa.

If the remote is removed, lost or damaged, signals transmitted to the receiver cease. Your fire will go to standby (pilot) mode after 6 hours.

2B TOUCH PAD CONTROL

2

AR1885

Press the ON-OFF button to light the appliance, (up to

30 seconds)

Press the UP button to increase the flame height

Press the DOWN button to decrease the flame height. At the lowest point it goes to ‘standby mode’, (only pilot

lit)

Press the ON-OFF button to turn the appliance off

5

Page 5
Image 5