E6581429
1. Press the [F4] key to carry out jog run.
The jog run frequency is displayed on the screen.
(In this example, the operation frequency is set at 5.0Hz.) Operation continues as long as the [F4] key is pressed, and it stops when the [F4] key is released.
Functions of function keys
F1 : Switches between Quick mode and Standard Setting mode.
F2 : Goes to the Language selection window.
F4 : Executes a jog run command.
Top View Mode
FWD | 60.0 Hz | JOG |
|
| 5.0 Hz |
Quick | Lng | JOG |
F1 | F2 | F4 |
| 3.3.5 Emergency stop / reset operation |
| To make an emergency stop or to reset the inverter, follow these steps. An emergency stop can be made when |
3 | operation is performed with the terminal board inputs (parameter CMOd=0, 2, 3 or 4). |
1. Press the [STOP/RESET] key. |
Blinking code “ EOFF ” is displayed in the upper right corner of the window.
2. Then press the [STOP/RESET] key again.
The Emergency Stop window appears and the blinking code “E” is displayed.
3. Then press the [STOP/RESET] key again.
The Trip window appears and the blinking code “CLr” is displayed.
| Top View Mode | EOFF |
|
|
|
|
|
FWD | 60.0 Hz | RUN |
|
| 60.0 Hz |
| |
| Emergency stop? |
|
|
|
|
|
|
Quick | Lng |
| |
|
|
|
|
| Top View Mode |
|
|
FWD | 60.0 Hz | Trip |
|
| E |
|
|
| Emergency stop |
|
|
|
|
|
|
Quick | Lng |
| |
|
|
|
|
| Top View Mode |
|
|
FWD | 60.0 Hz | Trip |
|
| CLr |
|
|
| Trip reset? |
|
|
|
|
|
|
Quick | Lng |
|
4. Last of all, press the [STOP/RESET] key once again to reset the inverter.