E6581429

4.2 Setting a basic parameter

When Quick mode is selected using the EASY key function, skip step 1. Go straight to step 2.

1. Select/confirm “Basic parameters” using the control dial.

The Basic Parameters window appears.

Functions of function keys

F1 : Goes to the Top View Mode.

F2 : Displays the previous window.

F3 : Displays the next window.

Parameter Setup Mode

Basic Parameters

AU1 :Automatic acc/dec

AU2 :Automatic torque boost

AU4 :Automatic function set CMOd :Command input mode FMOd :Frequency input mode 1

Top

F1 F2 F3

2. Select/confirm the parameter you want to change, using the control dial.

4

(Ex. Select/confirm “Command input mode” and “Base frequency 1.”)

The Parameter Setting window appears.

 

 

 

 

If the selected parameter is changed by selecting a

• If the setting selected is

 

 

menu item, the menu item selected is highlighted

changed by selecting a menu

 

and marked with a checkmark.

item

Functions of function keys

F2 : Displays the previous window.

F3 : Displays the next window.

Basic Parameters

CMOd

Command input mode

0

:Terminal

 

 

 

 

 

 

 

 

1

:Panel / LCD-option

 

 

 

 

 

 

 

 

2

:RS485-2wire

 

 

 

 

 

 

 

 

 

 

 

 

3

:RS485-3wire

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F2 F3

If the selected parameter is changed by specifying a value, the value specified is displayed. In addition, the minimum allowable value (min) and the maximum allowable value (max) are displayed at the bottom of the window.

Functions of function keys

The functions keys allow you to select the position or decimal place of each figure (operation frequency) you want to increment or decrement with the control dial.

F1 : Selects the position of 1000 times of minimum setting unit.

If the setting selected is changed by specifying a value

Basic Parameters

vL

Base frequency 1

60.0 Hz

min=25.0max=500.0

×1000 ×100 ×10 ×1

F2 : Selects the position of 100 times of minimum setting unit.

F1

F2

F3

F4

 

F3 : Selects the position of 10 times of minimum setting unit.

F4 : Selects the position of minimum setting unit (In this case, 0.1).

D-2