4.2Display and control parameters on remote control panel (optional)

STUDER Innotec

XP-COMPACT

 

 

4.2Display and control parameters on remote control panel (optional)

INVERTER - CHARGER

COMPACT

1

 

TRANSFER

8

 

A

%

AC IN

 

 

 

AC OUT

100

160

 

2

7

9

 

90

160

CHARGER

 

 

 

INVERTER

80

130

 

 

 

 

RESET

70

100

SOLAR CHARGE

 

 

 

60

80

 

 

20

ALARM

3

 

 

 

 

 

 

 

(Select)

50

60

EQUALIZE

14

10

Over Temp.

40

40

30

20

 

 

 

 

 

4 Program

 

15

11

Overload

20

10

 

12

Battery

10

5

 

 

 

5 Contact active

 

16

Low/High

Charger

Inverter

 

 

6 Contact manual

 

17

13

OFF

 

 

18

 

ON/OFF

 

25

AUXILIARY CONTACT

 

 

 

 

 

 

 

 

 

(Program)

 

 

 

(Change status)

 

21

 

 

19

 

 

 

RCC-01

4.3Light Emitting Diodes (LED)

LED

Marking

LED lit

LED blinks

 

1

AC IN

Voltage at the AC IN input is within

Voltage, outside of the self-

 

 

 

 

the accepted range (voltage and

adjusted values is at the AC IN

 

 

 

 

frequency)

input.

 

2*

CHARGER

Battery Charger is working

The input voltage is out value

 

 

 

 

 

(voltage or frequency)

 

3

SOLAR

Connected Solar modules are

 

 

 

 

CHARGE

delivering energy

 

 

4*

Program

Program mode for Aux. Contact

 

 

5*

Contact active

Auxiliary Contact is activated

 

 

6*

Contact manual

Aux. Cont. manually activated

 

 

7

 

Transfer system is active. Input

Transfer system (by-pass) is dis-

 

 

 

 

AC voltage is directly connected to

abled (see chap.6.5.1)

 

 

 

 

AC OUT outlet

 

 

8

AC OUT

Voltage is present at the AC OUT

The Inverter is in Standby mode.

 

 

 

 

outlet

No loads are detected at the out-

 

 

 

 

 

put

 

9*

INVERTER

Inverter is working

Inverter mode is disabled (see

 

 

 

 

 

chap.6.5.1)

 

10*

Over Temp.

For the time being the XP-

 

 

 

 

 

COMPACT is out of service be-

 

 

 

 

 

cause of overheating.

 

 

 

 

 

 

 

11*

Overload

The XP-COMPACT is out of ser-

Overload due to connection of the

 

 

 

 

vice because of overload or short-

grid or the generator at the output

 

 

 

 

circuit

of the inverter. Please Check the

 

 

 

 

 

 

 

 

 

 

 

 

User manual