S UB
PLUM BI NG REQU IREMENTS |
|
|
| |
WATE R S UPP LY AND DRAIN | L INE SIZIN G/ CO NN E CT I ON S |
| ||
|
|
|
|
|
| Water | Water | Ice Machine | Tubing Size up to |
| Temperature | Pressure | Fitting | Ice Machine Fitting |
|
|
|
|
|
Ice Making | 50°F (10°C) Min. | 20 psi (137.9 kPA) Min. | 1/4" (6.4) ID | 1/4" (6.4) minimum |
Water Inlet | 80°F (27°C) Max. | 80 psi (551.5 kPA) Max. | Copper Tubing | inside diameter |
|
|
|
|
|
Water Outlet |
|
| 3/4" (19) | 3/4" (19) minimum |
| — | — | Hose Barb | inside diameter |
|
|
|
|
|
|
|
|
|
|
Water Outlet |
|
| 3/8" (9.5) | 3/8" (9.5) |
| — | — | Hose | ID minimum |
|
|
|
|
|
|
|
|
|
|
NOTE: If air temperature is less than 60°F (16°C), water temperature must be equal to or greater than 50°F (10°C).
I M PO RTA N T NO T E
Plumbing must conform to state and local codes.
IMPORTANT NOTE: Although the ice machine has been designed to be serviced in place, in some cases it may be necessary to pull the unit out for service. For that reason do not restrict access to the unit at the front, top and bottom.
If a floor is to be installed after the ice machine, shims the thickness of the floor should be installed under the unit to keep the ice machine level with the floor. Also, allow
1/8" (3) clearance on each side of the unit for protruding screw heads.
Installations on a slab: Use a Model
Installations over a crawl space or
basement: If there is not enough room behind the ice machine for a drain/waste water receptacle, the drain will have to be below the floor.
Dimensions in parentheses are in millimeters unless otherwise specified.
9