11.TROUBLESHOOTING

11.TROUBLESHOOTING

11-1NO AC OUTPUT

11-1-1 CHECKING CONDENSER

1)Check the capacity of condensers using a ”Dr. R0bin”generator tester in capacitance meter mode.

NOTE : Be sure to discharge condensers by shorting condenser leads each other before checking their capacitance, or the accurate reading cannot be obtained.

RGX2410

RGX1810,

:

RGX5510

Fig. 1 1 - 1

I

NORMALCAPACITY OF CONDENSER

I

i

RGXl810 RGX5510RGX3510RGX2410

I

17yF 1 20yF 17,cF+20yF : 28,zFX2

Tzble 11-1

2)If such an instrument is unavailable,the condenser can be checked by replacing with a new one.If the vgenerator performs good with new condenser: the causeoftrouble is defect in original condenser.

11-1-2 CHECKING STATOR

1) Removecontrolpanel and disconnectstator wires at the connectors.

2)Measuretheresistancebetweenterminalson stator leads. (See Fig.11-2)

Refer to Table 9-1 for normal resistance.

If stator is faulty, replaceit with a new one.

Fig. 1 1-2