6-6 Sun Fire™ B1600 Chassis and B100s, B100x, and B200x Blade Product Notes • May 2004
the System Controller next time the switch boots. The command to change the
DHCP client identifier will be removed fromthe next release of the switch
firmware.
4795640: Resetting with the factory default configuration causes provisioning
errors
Saving a copy of the switch’s factory default configuration file (or saving a
modified copy of this file) generates errorsif the switch is then rebooted with the
saved copy specified as the startup configuration file.Youwill only see these
errors if you press p when asked if you want to view details of the startup
provisioning. The errors can be ignored.
4773404: No traffic statistics available for the NETMGT port
There is a known problem with the command for viewing trafficstatistics. The
output for the NETMGT port when you run the show interfaces counters
ethernet NETMGTcommand (from the console# prompt) contains zeroes instead
of valid data. There is currently no workaround for this problem.
4773404: No MAC address table available for the NETMGT port
(This issue has the same Sun number as the previous issue.) There is a problem
with the command for displaying the MAC address table for the NETMGT port.
The show mac-address-table interface ethernet NETMGT command
(from the console# prompt) always displays an empty table. Thereis currently
no workaround for this problem.
4789838: LACP sometimes fails if GVRP is enabled
There is a known problem with the operation of the link aggregation control
protocol and the dynamic VLAN configuration protocol GVRP.It is not possible
for the LACP protocolto operate reliably if GVRP is enabled. Therefore, if you are
using GVRP do not enable LACP.Firmware that fixes this problem is now
available from http://sunsolve.sun.com (patch number: 114783-xx).