Sun Microsystems Gigabit Ethernet MMF/UTP Adapter manual where

Models: Gigabit Ethernet MMF/UTP Adapter

1 122
Download 122 pages 59.52 Kb
Page 108
Image 108
where:

7.Use the test command and the device paths found in Step 6 to test the adapter when you use the FCode self-test.

The structure of the test command line includes the following device parameters:

ok test device-path:speed=s,duplex=d,link-clock=c,promiscuous,

where:

s = 1000, 100, 10, auto d = half, full, auto

c = master, slave, auto

Note – The speed, duplex, and link-clockparameters are optional tests.

The following default tests are run when you execute the test command:

Tests six groups of Ophir registers (You can see the names of the six groups in the output sample shown on the following page.)

Internal loopback test for the UTP card and external loopback test for the MMF card.

10 Mbps PHY loopback.

Refer to the appropriate OpenBoot Command Reference Manual for more information about the test command.

74 Sun PCI-Express Dual Gigabit Ethernet MMF/UTP Adapter Installation and User’s Guide • June 2006

Page 108
Image 108
Sun Microsystems Gigabit Ethernet MMF/UTP Adapter manual where