▼To Set Driver Parameters Using an ipge.conf File

To Set Driver Parameters Using an ipge.conf File

1.Obtain the hardware path names for the ipge devices in the device tree.

a.Check the /etc/driver_aliases file to identify the name associated with a particular device:

#grep ipge /etc/driver_aliases ipge "pciex8086,105e"

ipge "pciex8086,105f" ipge "pci8086,105e" ipge "pci8086,105f"

b.Locate the path names and the associated instance numbers in the

/etc/path_to_inst file.

#grep ipge/etc/path_to_inst "/pci@780/pci@0/pci@1/network@0" 0 "ipge" "/pci@780/pci@0/pci@1/network@0,1" 1 "ipge" "/pci@780/pci@0/pci@8/network@0" 2 "ipge" "/pci@780/pci@0/pci@8/network@0,1" 3 "ipge" "/pci@7c0/pci@0/pci@2/network@0" 4 "ipge" "/pci@7c0/pci@0/pci@2/network@0,1" 5 "ipge" "/pci@7c0/pci@0/pci@9/network@0" 6 "ipge" "/pci@7c0/pci@0/pci@9/network@0,1" 7 "ipge"

In this example:

The first part within the double quotes specifies the hardware node name in the device tree.

The number not enclosed in quotes is the instance number (shown in bold italics for emphasis).

The last part in double quotes is the driver name.

In the hardware node name, the last component after the last / character and before the @ character is the device name.

The path name before the last component is the parent name.

The number after the final @ character within quotes is the unit-address.

To identify a PCI-E device unambiguously in the ipge.conf file, use the name, parent name, and the unit-address for the device. Refer to the pci(4) man page for more information about the PCI-E device specification.

In this example:

parent = "/pci@7c0/pci@0/pci@2/network@0"

Chapter 3 Configuring ipge and e1000 Driver Parameters 27