SUPER MICRO Computer SuperServer 5016I-TF Checking the Serverboard Setup, Checking the Components

Models: SuperServer 5016I-T SuperServer 5016I-TF

1 98
Download 98 pages 30.5 Kb
Page 24
Image 24

SUPERSERVER 5016I-T/5016I-TF User's Manual

2-5 Checking the Serverboard Setup

After you install the 5016I-T/5016I-TF in the rack, you will need to open the unit to make sure the serverboard is properly installed and all the connections have been made.

Accessing the Inside of the System (Figure 2-5)

1.First, grasp the two handles on either side and pull the unit straight out until it locks (you will hear a "click").

2.Next, depress the two buttons on the top of the chassis to release the top cover. There is a large rectangular recess in the middle front of the top cover to help you push the cover away from you until it stops.

3.You can then lift the top cover from the chassis to gain full access to the inside of the server.

Checking the Components

1.You may have one or two processors already installed into the system board. Each processor should have its own heatsink attached. See Chapter 5 for instructions on processor and heatsink installation.

2.Your 5016T-TB server system may have come with system memory already installed. Make sure all DIMMs are fully seated in their slots. For details on adding system memory, refer to Chapter 5.

3.If desired, you can install an add-on card to the system. See Chapter 5 for details on installing a PCI add-on card.

4.Make sure all power and data cables are properly connected and not blocking the airflow. See Chapter 5 for details on cable connections.

5.Check the air seals for damage. The air seals are located under the blower fan and beneath the frame cross section that separates the drive bay area from the serverboard area of the chassis.

2-8

Page 24
Image 24
SUPER MICRO Computer SuperServer 5016I-TF Checking the Serverboard Setup, Accessing the Inside of the System Figure